A
B
2
1. Verify that AC power is switched OFF at the power source
before beginning.
2. Remove the junction box cover (two screws).
3. Use appropriate electrical conduit and fittings to route AC power
wire into the junction box. Run high voltage power wiring in separate
conduit from low voltage signal wiring.
4. Connect the power wires to the transformer wires with wire nuts
(see color code chart), and replace junction box cover.
5. Installer is responsible for local electrical codes and wiring.
Transformer
Hot
Neutral
Safety Ground
(required)
North America
(115VAC)
Black
White
Green
International
(230VAC)
Brown
Blue
Green with yellow stripe
CONNECT AC POWER .............................................................................................................