![Hunter IMMS-CI-HW Installation Instructions Manual Download Page 11](http://html1.mh-extra.com/html/hunter/imms-ci-hw/imms-ci-hw_installation-instructions-manual_2186407011.webp)
8
9
If the wrong address is set, reset the interface memory by
disconnecting the green three-wire power terminal. Press and hold
the green button, and plug the power terminal back in. Continue
holding the button until the test display “88” disappears, and release.
The display will show the version number for a moment, then the
“—“ display. Repeat the Controller Interface Address procedure to
enter the correct address.
INTERFACE RESET..................................................................................................................
Turn off or disconnect AC power plug before making any connections
inside the CI!
ADDITIONAL CONNECTIONS ................................................................................................
1. To connect to additional Controller Interfaces, route, strip, and
connect GCBL cable to the lower section of the CI communications
terminals in the same way that the incoming connection was made.
2. Connect the bare silver ground wire in the GCBL to the ground lug.
3. Continue the GCBL run to the next interface (IMMS-CI) in one
continuous run, if possible, with no breaks or splices in the
communications, and continue the installation.
CONNECTIONS TO OTHER INTERFACES ............................................................................