background image

42901-01  06/14/2010

3

E

F

G

H

I

L

M

N

95047-03-000

75864-02-000

03242-07-133

95261-02-000

74508-03-133

96397-01-214 for model 87001

96397-02-444 for model 87003

75184-01-133

86812-01-000 for model 87001

86812-03-000 for model 87003

J

77522-01

K

65219

O

75733-01-214 for model 87001

75733-01-444 for model 87003

x4

*

*

*

NOTE:

Strain relief cable 

connector must be 

installed. Not Included.

A

B

C

Extra Screws

x2

D

3/8” Cable Connector

x2

1

Turn off the power source.

Tools Needed. (Not supplied.)

Estimated assembly time: 30 to 60 minutes

  Before Installation

Check all the parts.  

If damaged, call  

1-888-830-1326  

for replacements.

Included.

2

E

I

Loosen screws.

NOTE: Remove all packing materials before installation.

Summary of Contents for Ashbury 87001

Page 1: ...42901 01 06 14 2010 1 Bath Ventilator with Light Owner s Manual Ashbury 48029 01 20100614 2010 Hunter Fan Co Model 87001 English ...

Page 2: ...me C A U T I O N W arning 1 Use this unit only in a manner intended by the manufacturer If you have questions contact the manufacturer 2 Before servicing or cleaning the unit switch power off at ser vice panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device...

Page 3: ...65219 O 75733 01 214 for model 87001 75733 01 444 for model 87003 x4 NOTE Strain relief cable connector must be installed Not Included A B C Extra Screws x2 D 3 8 Cable Connector x2 1 Turn off the power source Tools Needed Not supplied Estimated assembly time 30 to 60 minutes Before Installation Check all the parts If damaged call 1 888 830 1326 for replacements Included 2 E I Loosen screws NOTE R...

Page 4: ...ove the motor blower from the housing H E 3 Remove the pre loaded screw tip covers Remove the wiring cover screw 6 Back out the pre loaded screw tips until flush with the side of the housing Remove the wiring cover Remove packing material ...

Page 5: ...and secure with washer Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock New Construction 10 B C Choose Installation Option For New Construction go to step A11 page 5 For Existing Construction go to step B11 page 8 A11 E 5 8 1 2 5 8 1 2 A12 Screw pre loaded screws into joist or framing ...

Page 6: ...er Option Connect wires as shown A13 Route wires through the strain relief For supply connection use wires suitable for at least 90º C 194º F 0 0 A16 Connect 4 duct and vent to the outside Tape joints If ducting does not fit securely an adapter may need to be purchased A15 E F G Install the wiring cover plate Make sure all wiring connections are inside the box or under the wiring cover plate ...

Page 7: ...ween the motor and the housing Secure the motor by tightening the 2 screws Turn on the power source Connect wiring harness DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS 0 0 0 0 0 0 0 0 A17 0 0 0 0 0 0 0 0 H A18 ON OFF A21 Test the motor If the motor does not run check the plug connection A22 C1 Go to step on page 10 to attach grille ...

Page 8: ...xisting fan and check to make sure the opening is large enough to accommodate the new motor housing 7 1 4 x 7 3 4 Move the housing into position above the ceiling Attach existing ducting to duct connector Tape joints If ducting does not fit securely an adapter may need to be purchased E B15 Install the housing flush with the sheetrock and secure by tightening the pre loaded screws into the joist ...

Page 9: ...e housing Connect wiring harness DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS Secure the motor by tightening the 2 screws A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper Ground B16 Main Switch 1 AC In Switch 2 AC In Option Fan Main Light Together Option Connect wires as shown F B17 G Install the wiring cover plate ...

Page 10: ... OFF B22 B23 C1 Go to step on page 10 to attach grille B21 Test the motor If the motor does not run check the plug connection Turn on the power source L O C2 N M C1 Attaching the Grille Remove the thumbscrews Remove glass dome ...

Page 11: ...ver the lip of the motor Reinstall the strain relief bracket screw L C3 Connect wiring harness DO NOT ALLOW THE FIXTURE TO HANG FROM THE WIRING HARNESS C7 L L C8 M Align posts 1 2 and 3 stamped into motor housing with posts 1 2 and 3 stamped into light fixture Slide light fixture over posts Attach thumbscrews WARNING To reduce the risk of electrical shock all 3 thumbscrews MUST be properly install...

Page 12: ...42901 01 06 14 2010 12 C9 C10 N O C11 Align glass dome and push up Install 2 Max 60 Watt A15 bulbs Not Included Screw glass dome into position ...

Page 13: ...sure it matches the wiring diagram Problem Light does not come on Solution Replace the light bulb with a new bulb Turn power on replace fuse or reset breaker Check all plug connections to be sure they are secure Check the wiring to make sure it matches the wiring diagram Problem Fan is noisy Solution Check and tighten all fasteners Check the glass to make sure it is secure Check the flapper to mak...

Page 14: ... EXPRESS WARRANTIES THE DURATION OF ANY IMPLIED WARRANTY INCLUD ING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN RESPECT TO ANY HUNTER FAN BATH EXHAUST FAN MOTOR OR OTHER FAN PART IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE FOR SUCH MOTORS OR OTHER PARTS This warranty is voided if your Hunter bath exhaust fan is no...