Hunter ARCHITECT 90061 Installation Manual Download Page 2

x2

x4

D

E

F

G

H

I

K

M

95044-01-000

95022-01-000

75190-01-000

95492-01-000

94999-01-000

75174-01-000

L

J

75184-01-133

74508-03-133

95492-01-000

x3

3/8" Cable Connector

*

*

NOTE:

Strain relief cable connector            
must be installed. Not Included.

A

B

C

Extra Screws

x2

I

2

3

 DISCONNECT 

ELECTRIC 

POWER SUPPLY 

AND LOCK OUT 

SERVICE PANEL 

BEFORE 

SERVICING UNIT

  W A R N I N G

TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING:

1.

  For general ventilating use only. Do not use for ventilat-

ing hazardous or explosive materials.

2.  

To avoid motor bearing damage and noisy/unbalanced 
impellers, keep drywall spray, construction dust, etc. off 
power unit.

3.

  DO NOT install this product in a wall. This product is 

designed for installation in ceilings up to a 12/12 pitch 
(45 degrees). Ductwork must point upward.

4.

  Please read specification label on product for further 

information and requirements.

PREVENTATIVE MAINTENANCE

A clean fan provides better service. Disconnect the power supply and clean the fan as listed below.

TO CLEAN GRILLE:

 Use a mild detergent, such as dishwashing liquid, and a soft cloth. DO NOT use abrasive cloths, steel 

wool pads or scouring powders.

TO CLEAN FAN ASSEMBLY:

 Unplug motor cord from receptacle. To remove motor plate, find the single tab on the motor 

plate (located next to the receptacle). Push up rear motor plate tab while pushing out on the side of the housing or insert a 
screwdriver into the slot in the housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing.

METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.

MAINTENANCE

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual 
noises, replace the motor with the exact service motor. You should replace the impeller at the same time.

 

C A U T I O N

  W A R N I N G

1.

  Use this unit only in a manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the phone 
number or address listed in the warranty.

2.

  Before installing, servicing, or cleaning the unit,  

disconnect the power by turning off the circuit breakers to 
the outlet box and associated wall switch location. If you 
cannot lock the circuit breakers in the off position, securely 
attach a prominent warning device, such as a tag, to the 
service panel.

 

3.

  Installation work and electrical wiring must be done by 

qualified person(s) in accordance with all applicable codes 
and standards, including fire-rated construction codes and 
standards.

4.

  Sufficient air is needed for proper combustion and exhaust-

ing of gasses through the flue (chimney) of fuel burning 
equipment to prevent backdrafting. Follow the heating  
equipment manufacturer’s guideline and safety standards, 

   such as those published by the National Fire Prevention 

Association (NFPA), and the American Society for Heating, 
Refrigeration and Air-Conditioning Engineers (ASHRAE), and 
the local code authorities.

  5.

  When cutting or drilling into wall(s) or ceiling, do not  

damage electrical wiring or other hidden utilities.

  6.

  Ducted fans must always be vented to the outdoors. Keep 

ducting as short and as straight as possible.

  7.

  Acceptable for use over a bathtub or shower when  

connected to a GFCI protected branch circuit.

  8.

 Install fan at least 5 feet (1.52 m) above the floor.

  9.

  Never place a switch where it can be reached from a tub  

or shower.

10.

 This unit must be grounded.

OFF

30

OF

F

30

OF

F

20

30

OF

F

30

OFF

30

2

1

Turn off the power source.

Tools Needed.

Estimated assembly time: 30 to 60 minutes

 

Before Installation

Check all the parts. 

If damaged, call

 

1-888-830-1326 

for replacements.

Included.

2

E

I

Loosen screws.

 

41721-01  12/25/2004

 

41721-01  12/25/2004 

NOTE: Remove all packing materials before installation.

Summary of Contents for ARCHITECT 90061

Page 1: ... BULBS OR THE FINISH ON ANY METAL PORTION OF THE BATH EXHAUST FAN THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES THE DURATION OF ANY IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN RESPECT TO ANY HUNTER FAN BATH EXHAUST FAN MOTOR OR OTHER FAN PART IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FO...

Page 2: ...motor You should replace the impeller at the same time C A U T I O N W A R N I N G 1 Use this unit only in a manner intended by the manufacturer If you have questions contact the manufacturer at the phone number or address listed in the warranty 2 Before installing servicing or cleaning the unit disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch l...

Page 3: ...truction attaching to joist go to step A11 page 5 For New Construction suspended between joists go to step B11 page 8 For Existing Construction accessible from above go to step C11 page 11 For Existing Construction accessible only from below go to step D11 page 14 E A11 5 8 1 2 5 8 1 2 A12 Remove the pre loaded screw tip covers Remove the wiring cover screw Screw pre loaded screws into joist or fr...

Page 4: ...ng the tabs and pushing up into position Make sure the wires are not pinched between the motor and the housing Secure the motor by tightening the 2 screws A21 ON OFF A22 Test the motor If the motor does not run check the plug connection Turn on the power source Connect 4 duct and vent to the outside Tape joints If ducting does not fit securely an adapter may need to be purchased Connect wiring fro...

Page 5: ...ite Bare Copper Ground B19 B D B18 Tighten screws B17 Attach the rails onto the screws Insert screws leaving space between the screw head and the joist Screws are not provided B15 B16 New Construction suspended between joists 8 9 B20 2 F F 1 B21 2 G Install the wiring cover plate Make sure all wiring connections are inside the box or under the wiring cover plate Tighten the wiring cover plate scre...

Page 6: ...e wiring cover plate 10 11 Existing Construction accessible from above EXISTING FAN C11 Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing 9 x 9 75 NO EXISTING FAN Use the motor housing as a template to mark position 9 9 7 5 Cut out an opening for the housing C12 D Slide the mounting rails into brackets OR 5 8 1 2 5 8 1 2 C13 Position the...

Page 7: ...rain relief 12 13 C20 C21 Tighten the strain relief screws Connect wires as shown C23 F 1 2 Install the wiring cover plate Make sure all wiring connections are inside the box or under the wiring cover plate A A A Green Black White Bare Copper Ground C22 B D C24 G Tighten the wiring cover plate screw C25 Connect wiring from the motor to the wiring cover plate C26 H Reinstall the motor by inserting ...

Page 8: ...ew motor housing 9 x 9 75 Move the housing into position above the ceiling D13 2 1 D14 Pull wires through strain relief Attach existing ducting to duct connector Tape joints If ducting does not fit securely an adapter may need to be purchased E D15 Screw pre loaded screws into joist or framing A A A Green Black White Bare Copper Ground D16 B D D17 F 1 2 Connect wires as shown Install the wiring co...

Page 9: ... on the power source ON OFF D23 D24 E1 Go to step on page 17 to attach grille Test the motor If the motor does not run check the plug connection K L M E2 K H E3 K J E4 Slide light mount over posts Attach thumbscrews WARNING To reduce the risk of electrical shock all 4 thumbscrews MUST be properly installed Align dome and push up K E5 L Screw dome into position J H E1 Attaching the Grille Remove th...

Page 10: ...ure they are secure Check the wiring to make sure it matches the wiring diagram Problem Fan is noisy Solution Check and tighten all fasteners Check the glass to make sure it is secure Check the flapper to make sure it moves freely If you need parts or service assistance please call 888 830 1326 or visit us at our WEB site at http www hunterfan com 41721 01 12 25 2004 41721 01 12 25 2004 Paint the d...