background image

 I

n

s

t

a

l

l

a

t

i

o

n

 

G

u

i

d

e

 

90061 Architect™ Bath Ventilator

2500 Frisco Avenue, Memphis, Tennessee 38114

Printed in China

 

41721-01  12/25/2004

 

41721-01  12/25/2004 

 

Warranty

Hunter Fan Company

Bath Exhaust Fan

LIMITED WARRANTY

Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath  

exhaust fan:

If any part of your Hunter bath exhaust fan (except for glass fixtures and light bulbs) fails at any time within one year after the date 

of sale to you due to a defect in material or workmanship, we will repair or, at our option, replace the defective part free of charge 

for parts and labor performed at our nearest service center or at our Service Department in Memphis, Tennessee.  After this one-year 

period, you will be responsible for all parts and labor costs for repairs on the bath exhaust fan except for motor repairs as 

provided below.

If your Hunter bath exhaust fan motor fails at any time within five years after the date of sale to you due to a defect in material or 

workmanship, labor and materials to repair the defect will be provided free of charge at our nearest service center or our Service 

Department in Memphis, Tennessee.  If no replacement part can be provided, we will, at our option, either refund the actual purchase 

price of your bath exhaust fan or provide a replacement free of charge. After this five-year period, you will be responsible for all parts 

and labor costs for repairs on all parts of the bath exhaust fan.  

IF THE ORIGINAL USER OR CONSUMER PURCHASER CEASES TO OWN THE FAN, THIS WARRANTY AND ANY IMPLIED WARRANTY WHICH 

THEN REMAINS IN EFFECT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A  

PARTICULAR PURPOSE, ARE VOIDED. NO WARRANTY, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR 

FITNESS FOR A PARTICULAR PURPOSE, IS MADE IN RESPECT OF GLASS FIXTURES OR LIGHT BULBS OR THE FINISH ON ANY METAL 

PORTION OF THE BATH EXHAUST FAN.

THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES. THE DURATION OF ANY IMPLIED WARRANTY, INCLUDING, BUT NOT 

LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IN RESPECT TO ANY HUNTER 

FAN BATH EXHAUST FAN MOTOR OR OTHER FAN PART, IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH 

ABOVE FOR SUCH MOTORS OR OTHER PARTS.

This warranty is voided if your Hunter bath exhaust fan is not purchased and installed in the U.S.A. This warranty excludes and does 

not cover defects, malfunctions or failures of any Hunter bath exhaust fan which were caused by repairs by persons not authorized by 

us, use of parts or accessories not authorized by us, mishandling, improper installation, modifications or damage to the Hunter bath 

exhaust fan while in your possession, or unreasonable use, including failure to provide reasonable and necessary maintenance.

To obtain servicing, contact the nearest Hunter authorized service center of the Hunter Fan Company Service Department, 2500 

Frisco Avenue, Memphis, Tennessee 38114. Please contact us before shipping your bath exhaust fan to us. If we authorize you to 

ship it to us, you will be responsible for all insurance and freight or other transportation charges to our factory or service center. We 

will return your Hunter bath exhaust fan freight prepaid. Your Hunter bath exhaust fan should be properly packed to avoid damage in 

transit since we will not be responsible for any such damage. Proof of purchase is required when requesting warranty service. The 

purchaser must present the sales receipt or other document that establishes proof of purchase.

IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES.

SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATION OF 

INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSIONS MAY NOT APPLY TO YOU.

THE WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE

Summary of Contents for ARCHITECT 90061

Page 1: ... BULBS OR THE FINISH ON ANY METAL PORTION OF THE BATH EXHAUST FAN THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES THE DURATION OF ANY IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN RESPECT TO ANY HUNTER FAN BATH EXHAUST FAN MOTOR OR OTHER FAN PART IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FO...

Page 2: ...motor You should replace the impeller at the same time C A U T I O N W A R N I N G 1 Use this unit only in a manner intended by the manufacturer If you have questions contact the manufacturer at the phone number or address listed in the warranty 2 Before installing servicing or cleaning the unit disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch l...

Page 3: ...truction attaching to joist go to step A11 page 5 For New Construction suspended between joists go to step B11 page 8 For Existing Construction accessible from above go to step C11 page 11 For Existing Construction accessible only from below go to step D11 page 14 E A11 5 8 1 2 5 8 1 2 A12 Remove the pre loaded screw tip covers Remove the wiring cover screw Screw pre loaded screws into joist or fr...

Page 4: ...ng the tabs and pushing up into position Make sure the wires are not pinched between the motor and the housing Secure the motor by tightening the 2 screws A21 ON OFF A22 Test the motor If the motor does not run check the plug connection Turn on the power source Connect 4 duct and vent to the outside Tape joints If ducting does not fit securely an adapter may need to be purchased Connect wiring fro...

Page 5: ...ite Bare Copper Ground B19 B D B18 Tighten screws B17 Attach the rails onto the screws Insert screws leaving space between the screw head and the joist Screws are not provided B15 B16 New Construction suspended between joists 8 9 B20 2 F F 1 B21 2 G Install the wiring cover plate Make sure all wiring connections are inside the box or under the wiring cover plate Tighten the wiring cover plate scre...

Page 6: ...e wiring cover plate 10 11 Existing Construction accessible from above EXISTING FAN C11 Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing 9 x 9 75 NO EXISTING FAN Use the motor housing as a template to mark position 9 9 7 5 Cut out an opening for the housing C12 D Slide the mounting rails into brackets OR 5 8 1 2 5 8 1 2 C13 Position the...

Page 7: ...rain relief 12 13 C20 C21 Tighten the strain relief screws Connect wires as shown C23 F 1 2 Install the wiring cover plate Make sure all wiring connections are inside the box or under the wiring cover plate A A A Green Black White Bare Copper Ground C22 B D C24 G Tighten the wiring cover plate screw C25 Connect wiring from the motor to the wiring cover plate C26 H Reinstall the motor by inserting ...

Page 8: ...ew motor housing 9 x 9 75 Move the housing into position above the ceiling D13 2 1 D14 Pull wires through strain relief Attach existing ducting to duct connector Tape joints If ducting does not fit securely an adapter may need to be purchased E D15 Screw pre loaded screws into joist or framing A A A Green Black White Bare Copper Ground D16 B D D17 F 1 2 Connect wires as shown Install the wiring co...

Page 9: ... on the power source ON OFF D23 D24 E1 Go to step on page 17 to attach grille Test the motor If the motor does not run check the plug connection K L M E2 K H E3 K J E4 Slide light mount over posts Attach thumbscrews WARNING To reduce the risk of electrical shock all 4 thumbscrews MUST be properly installed Align dome and push up K E5 L Screw dome into position J H E1 Attaching the Grille Remove th...

Page 10: ...ure they are secure Check the wiring to make sure it matches the wiring diagram Problem Fan is noisy Solution Check and tighten all fasteners Check the glass to make sure it is secure Check the flapper to make sure it moves freely If you need parts or service assistance please call 888 830 1326 or visit us at our WEB site at http www hunterfan com 41721 01 12 25 2004 41721 01 12 25 2004 Paint the d...

Reviews: