background image

4

  47009-01  02/16/2012

SAFETY AND WARNINGS (CONTINUED)

9. 

  To disconnect, grip plug and pull from wall outlet. 

NEVER

 pull directly on cord.

10. 

This product is intended for residential use only and not for commercial or industrial use.

11. 

DO NOT

 operate fan in the presence of explosive and/or flammable fumes, or freezing temperatures.

12. 

This appliance has a grounded three-prong plug and is suitable for grounded receptacle use only. 

DO NOT

     

  attempt to defeat the purpose of this safely feature.

13. 

DO NOT

 use an extension cord to plug this unit into an outlet.

14. 

This fan is provided with a ground fault circuit interrupter (GFCI) built into the plug of the power supply cord. This 

device provides additional protection from the risk of electric shock. DO NOT attempt to disconnect or bypass 

this safety feature.

15. 

DO NOT

 run the fan for extended periods of time unattended.

16. 

This fan is intended for outdoor use.

17. 

DO NOT 

attempt to mount or hang this fan from a wall or ceiling.

18. 

Exposure to sunlight for extended periods of time may fade the appearance of this product.

UNPACKING

As you unpack the fan, save the carton and packing materials in case you want to move or ship the unit in the future. 
Carefully remove all items from the box.

NOTE:

 It is best to have someone hold the box while you lift the fan and the protective packaging out of the carton. 

Make sure all shipping materials are removed from fan before operating.

Summary of Contents for 90398

Page 1: ...16 Outdoor Stand Fan 18 Outdoor Stand Fan 18 Outdoor Stand Fan with Misting Feature Owner s Manual Model 90398 English Form 47009 01 20120216 2012 Hunter Fan Co ...

Page 2: ... and Warnings 3 Unpacking 4 Parts List 5 Base Assembly 6 Attaching Motor to Base Assembly 6 Grill Assembly 6 Misting Ring Installation 7 Operation and Adjustments 7 Maintenance 9 Troubleshooting 9 Technical Support 10 Warranty 11 Products 12 ...

Page 3: ...to reduce the risk of fire electric shock and personal injury Read and save these instructions 1 Improper installation may result in the risk of fire electric shock or personal injury 2 The power plug must be unplugged from the power socket when not in use before cleaning servicing maintenance and before moving to another location 3 The fan should be placed on a flat stable surface to avoid overtu...

Page 4: ...errupter GFCI built into the plug of the power supply cord This device provides additional protection from the risk of electric shock DO NOT attempt to disconnect or bypass this safety feature 15 DO NOT run the fan for extended periods of time unattended 16 This fan is intended for outdoor use 17 DO NOT attempt to mount or hang this fan from a wall or ceiling 18 Exposure to sunlight for extended p...

Page 5: ...ll 1 F Grill Ring 1 G Motor Shaft 1 H Fan Speed Knob 1 I Oscillation Knob 1 J Motor Housing 1 K Tilt Adjustment Knob 1 L Motor Housing Pole 1 M Power Cord 1 N GFCI 1 O Motor Housing Screws 4 P Height Adjustment Knob 1 Q Motor Housing Pole Screw 1 R Internal Pole 1 S External Pole 1 T Cord Clip 1 U Base 1 V Weight 1 W Large Washer 1 X L Bolt 1 Y Valve 1 Z Misting Line 1 ...

Page 6: ...to feed it into the threaded end of the External Pole Continue to hand tighten until secure Figure 1 4 Tip the Base assembly back upright 5 Grasp the Height Adjustment Knob P and twist counter clockwise to loosen 6 Raise the Internal Pole R and tighten the Height Adjustment Knob by twisting clockwise until secure 1 Remove Blade Cap C from Motor Shaft G by turning the Blade Cap clockwise Figure 2 2...

Page 7: ...ed Figure 6 Tilt Adjustment To adjust the angle the fan is blowing 1 Loosen the Tilt Adjustment Knob K located on the Motor Housing Pole L 2 Adjust the fan to desired angle and then retighten the Tilt Adjustment Knob to secure the fan at that angle Figure 6 5 Install the Blade Cap C by hand tightening in a counter clockwise direction 6 Place the Front Grill B against the Rear Grill E so that the H...

Page 8: ...e from the hose GFCI Operation The GFCI on the plug of this fan has 2 buttons Test and Reset If you wish to see if the GFCI circuit is functioning properly press the Test button The fan will immediately shut off as if the GFCI has been activated and the window between the buttons nn will change to black Figure 8 This lets you know the GFCI circuit has been activated Press the Reset button and the ...

Page 9: ... vinegar for 2 hours 3 Rinse each nozzle with water and place back into the front fan grill 4 Twist clockwise until secure DO NOT over tighten Warning Before cleaning your Hunter fan turn the unit off unplug it and disconnect the water hose from the misting valve Never use harmful or abrasive chemicals and ALWAYS unplug the fan 1 Problem Misting feature sputters or does not mist at all Solution En...

Page 10: ...oscillation knob on the fan is pressed in 5 Problem GFCI continues to activate Solution Try using a different power outlet Unplug the unit and contact our Technical Support Department USA 1 888 830 1326 Canada 1 866 268 1936 Hours of operation are from 7 00 am to 7 00 pm Monday Friday and 8 00 am to 5 00 pm on Saturday Central Time You may also contact us on the Internet at www HunterFan com TECHN...

Page 11: ...his Tennessee IF THE USER OR CONSUMER PURCHASER CEASES TO OWN THE FAN THIS WARRANTY AND ANY IMPLIED WARRANTY WHICH THEN REMAINS IN EFFECT INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE VOIDED NO WARRANTY EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS MADE IN RESPECT TO THE GLASS GLO...

Page 12: ...or other transportation charges to our factory service center We will return your Hunter Fan freight prepaid Your portable fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage Proof of purchase is required when requesting warranty service The purchaser must present sales receipt or other document that establishes proof of purchase IN NO EVEN...