![Hunter 80500 Installation Manual Download Page 18](http://html.mh-extra.com/html/hunter/80500/80500_installation-manual_2184808018.webp)
42922-0 2/29/06
8
Trouble Shooting
problem: Fan does not come on.
Solution:
• Turn power on, replace fuse, or reset breaker.
• Hunter Fan Bath Ventilators are extremely quiet. To confirm that the fan is running, place your hand near
the vents to feel the air movement.
• Check all plug connections to be sure they are secure.
• Check the wiring to make sure it matches the wiring diagram.
problem: Light does not come on.
Solution:
• Replace the light bulb with a new bulb.
• Turn power on, replace fuse, or reset breaker.
• Check all plug connections to be sure they are secure.
• Check the wiring to make sure it matches the wiring diagram.
problem: Fan is noisy.
Solution:
• Check and tighten all fasteners.
• Check the bezel to make sure it is secure.
• Check the flapper to make sure it moves freely.
If you need parts or service assistance, please call 888-830-326 or visit us at our WEB site at http://www.
hunterfan.com.
A clean fan provides better service. Disconnect the power supply and clean the fan/heater as listed below.
TO CLEAN THE BEZEL: Remove the finial and the bezel thumbnut. Remove the bezel. Use water, a mild detergent
such as dishwashing liquid, and a soft cloth to clean the bezel. DO NOT use abrasive cloths, steel wool pads, or
scouring powders.
TO CLEAN THE FAN/HEATER ASSEMBLY: Disconnect power to the unit by switching off the breaker or removing
the fuse. Turn the wall switch off. Remove the bezel (as described above). Remove the three thumbnuts and the
locknut from the lighting assembly. Unplug the lighting assembly wire harness. Loosen the fan assembly’s two
attachment crews. Remove the fan assembly from the housing and unplug the fan assembly wiring harness.
Gently vacuum the fan, motor, and the housing interior.
Reinstall and plug in (in this order) the fan assembly and the light assembly. Re-attach the bezel.
Restore power to the appliance. Test the appliance. If the fan does not run, ) check the power source, or 2) dis-
connect power to the appliance, disassemble as described above, check the fan assembly plug, restore power,
and test the unit. If the fan still does not run, contact a qualified installer.
NEVER IMMERSE METAL OR ELECTRICAL COMpONENTS IN WATER.
preventative Maintenance
Maintenance
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or
unusual noises, contact Hunter Technical Support (see Troubleshooting section) to order a new service motor.
Summary of Contents for 80500
Page 20: ...42922 01 12 29 06 20 ...