17
InSTAllInG THE THErMOSTAT, COnT.
COnnECTInG THE WIrES
1. loosen, but do not remove, the terminal screws.
note: A jumper wire has been provided, connecting the
rC and rH terminals for systems that do not provide both
an rH and rC wire. If you have both an rH and rC wire,
remove this jumper. If you do not have both an rH and rC
wire, leave the jumper in place.
2. Match and connect the wires from the wall to the
terminals as shown. Wires should be inserted behind the black
terminal shields. Tighten each screw after the connection has
been made.
(The ends of any extra wires should be individually wrapped in electrical
tape and carefully pushed back into the wall.)
3. Push any excess wire length back into the wall to prevent
interference.
G RC RH Y W
Jumper
Summary of Contents for 42710-01
Page 2: ...2...
Page 8: ...8 Y RC G W Y RC G W...
Page 12: ...12 W B R C G Y 0 Y 1...
Page 14: ...14 W R C Y G...
Page 16: ...16 G RC RH Y 0W B R C G Y1 Y 0 W B Y 1 Terminal Shield...
Page 20: ...20 1 2 front cover Tab...
Page 22: ...22 reset...
Page 24: ...24 day time AM PM program...
Page 26: ...26 AM HEAT 4 T...
Page 28: ...28 AM HEAT 2 TH...
Page 30: ...30 hold return system off heat cool HOLD...
Page 32: ...32 home today HOMETODAY...
Page 34: ...34 Set Temp...
Page 38: ...38 AM PM program hold return system off heat cool...
Page 40: ...40 AM PM HEAT COOL 2 1 3 4 M T W TH F SA SU program hold return system off heat cool...
Page 42: ...42 filter FILTER...
Page 44: ...44 energy Usage Today Min Hr...
Page 46: ...46 HEAT COOL system off heat cool reset...
Page 48: ...48 STAGE 1 PM COOL 4 M STAGE 2...
Page 50: ...50 hold return...
Page 52: ...52...