aIr purIfIer maInTenanCe

It is necessary to periodically check your Air Purifier for 

performance.  If  the  Pre-Filter  and/or  Permanent  HEPA 

Filter are covered in dust and other captured particles, it 

will be necessary to clean one and or both. The Pre-Filter 

and Filter should be checked at least every 6 months. The 

UVC Light should be replaced every year.

NOTE:

 Some environments may require more frequent 

cleaning of each filter. In these situations, adjust the time 

you check your filters to ensure the filters stay clog free to 

optimize performance.

figure 7.

Press 

Down

operaTIng your aIr purIfIer

OFF 

  Unit off

 

  Low speed - Recommended for use when soft  

 

  background noise is unwanted.

         Medium speed - Typical usage setting. Soft  

 

  background noise is not an issue.

      High speed - Use when quick, efficient results  

  

 to a room’s air quality are desired.

The fan speed can be adjusted at any time by rotating the 

dial so the indicator light aligns with the desired speed.
Press the UVC Light Button to turn on and off the UVC 

function of your Air Purifier.
Press the Ionizer button to turn on the Ionizer function of 

your air purifier. The Ionizer light will illuminate while the 

ionizer is active.

NOTE: 

The ON/OFF Indicator and the UVC Indicator 

will stay lit while the fan and/or UVC is running.

figure 6.

UVC ON/OFF

Speed 

control

ON/OFF

ON/OFF

Indicator

UVC 

Indicator

Check or Clean your pre-filter

1.  Turn the Air Purifier off and disconnect from the wall.

2.  Remove  the  rear  grill  on  the  back  of  the  unit  by 

pressing  the  tab  at  the  top  of  the  unit,  under  the 

handle and pull the rear grill outward. Figure 7.

3.  Turn  the  Rear  grill  over  and  gently  remove  the  Pre-

Filter from the grill.

4.  Check the Pre-Filter side facing the grill for particle 

coverage.

IONIZER ON/OFF

Summary of Contents for 30835

Page 1: ...Ionizer Total Air Purification Total Air Purification Total Air Purification Form 44091 01 20101005 2010 Hunter Fan Co Permanent HEPA Air Purifier Owner s Manual Model 30839 30842 English...

Page 2: ...Purifier 5 How The System Works 6 Operating Your Air Purifier 7 Air Purifier Maintenance 7 Check or Clean Your Pre Filter 7 Check or Clean Your Filter 8 Replace The UVC Bulb 8 Cleaning the Unit 9 Trou...

Page 3: ...er The ionizer improves the quality of air in the room by releasing negative ions into the air that attract positively charged dust smoke and pollen particles Safety Instructions 1 WARNING This Air Pu...

Page 4: ...uct if the cord has been damaged 6 To reduce the risk of electric shock this product has a polarized plug one blade is wider than the other as a safety feature This plug will fit into a polarized outl...

Page 5: ...e 2 4 The washable Pre Filter is mounted inside the back grill of the unit Confirm that it properly covers the grill vents 5 The Permanent HEPA Filter will be resting inside the unit If present remove...

Page 6: ...can be captured The UVC Light helps kill particles not trapped on the Permanent HEPA Filter and the Photocatalytic Oxidation screen removes harmful VOC s The ionizer charges any remaining particles c...

Page 7: ...High speed Use when quick efficient results to a room s air quality are desired The fan speed can be adjusted at any time by rotating the dial so the indicator light aligns with the desired speed Pre...

Page 8: ...se the filter with warm water and allow to dry completely Note Wet parts placed into the unit can cause damage to the filters and or the motor of the Air Purifier Check or Clean Your Filter 1 Turn the...

Page 9: ...gure 13 Do not over tighten Discard the bag 9 Reinsert the Bulb carrier into the unit at a 45o angle and turn clockwise to lock into the Air Purifier Note If the UVC Bulb door is not re installed corr...

Page 10: ...be cleaned See Check or Clean Your Filter on page 10 Problem The UVC Lamp is not operating Solution 3 3 Check the installation of the UVC Bulb 3 3 Replace the UVC Bulb See Replace The UVC Bulb on page...

Page 11: ...ranty to the original residential user or consumer purchaser of the Total Air Purification System If any part of your Total Air Purification System Air Purifier motor fails during the first five 5 yea...

Page 12: ...sed by repairs by persons not authorized by us use of parts or accessories not authorized by us mishandling modifications or damage to the Air Purifier while in your possession or unreasonable use inc...

Page 13: ...ALLOW THE EXCLUSION OR LIMITATION OF DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU SOME AMERICAN STATES AND CANADIAN PROVINCES DO NOT ALLOW...

Page 14: ...14 2010 Hunter Fan Co 44091 01 20101005 Printed in china and Taiwan Filter and UVC Calendar Pre Filter Perma Filter UVC Bulb Date of Replacement or Cleaning Notes...

Reviews: