Operation

Filter Life Counters

The pre-filter and filter are critical to the proper operation of the air purifier. To help you
know when to change the filters, your Hunter Air Purifier has Filter Life Counters that will
monitor the percentage of life your filter has left. Although the exact life of the filters de-
pends on the environment, the table below gives typical usage times of the filters.

Table 2: Typical Usage Times of the Filters

Filter Type

Typical  Usage

Activated Carbon Pre-Filter

2000 hours

HEPA Filter

8000 hours

The display shows the percentage of life left since the counter was reset. NOTE: The per-
centage level drops in 5% increments.

The values of the Pre-Filter and Filter Life Counters are stored in the air purifier’s
memory. The unit may be unplugged and moved or stored without losing the Pre-
Filter and Filter Counter values.

To properly track filter usage, the Pre-Filter and Filter Life Counters should be reset each
time the filters are changed. Refer to Changing the Pre-Filter (pg. 10) or Changing the Filter
(pg. 11) for instructions on how to reset the counters.

Locking/Unlocking the Keypad

Once you enter the desired speed, you may want to lock the keypad to prevent accidental
changing of the speed. When the keypad is locked, all keys will be disabled. If you press a
key, the Keypad Locked Indicator will be displayed on the screen for 1-2 seconds.

To Lock or Unlock the Keypad:

1. To lock the keypad, press and hold the OFF/SPEED and

TURBO keys simultaneously for 2-3 seconds. The Key-
pad Locked Indicator will appear on the display. Refer to
Fig. 9. After releasing the keys, the Keypad Locked Indi-
cator will disappear.

2. To unlock the key pad, press and hold the OFF/SPPED

and TURBO keys simultaneously for 2-3 seconds. The
Keypad Indicator will disappear and the keypad will be
functional.

Fig. 9

41791-01_rev 08.02.05.pmd

8/2/05, 3:29 PM

8

Summary of Contents for 30735

Page 1: ...rfan com Model 30735 30736 41791 01 08 02 2005 2005 Hunter Fan Company Replacement Filter Information Pre Filter 30901 30901 HEPA Filter 30960 30960 Model 30735 30736 41791 01_rev 08 02 05 pmd 8 2 05...

Page 2: ...ration 6 Filter Life Counters 8 Locking Unlocking the Keypad 8 Resetting the Air Purifier 9 Using the Ionizer 9 Controlling the Backlight 9 Air Purifier Maintenance Cleaning Your Air Purifier 10 Chang...

Page 3: ...E ALL INSTRUCTIONS Introduction Thank you for purchasing the QuietFlo Ultra Ionizing HEPA Air Purifier from Hunter Fan Company You have purchased our latest development in portable air purification wh...

Page 4: ...ns Ionizer How the QuietFlo Ultra Ionizing HEPA Air Purifier System Works As the air is pulled into the purifier the activated carbon pre filter absorbs odors and catches large particles Then the air...

Page 5: ...Life Counter FILTER RESET Resets the HEPA Filter Life Counter IONIZER KEY Turns the ionizer on and off Fig 3 Air Purifier Control Area and Alpha numeric Display PRE FILTER LIFE COUNTER KEYPAD LOCKED I...

Page 6: ...become loose during shipping To check the filters first open the front grill Release the front grill by placing your fingers under the handle on the grill and pull forward then up Refer to Figs 4 and...

Page 7: ...ion Fig 6 Fig 7 6 Plug the unit into a 120V electrical outlet and press the OFF SPEED key The air purifier will start with a low blower speed 7 Use the OFF SPEED and TURBO keys to adjust the blower sp...

Page 8: ...and Filter Counter values To properly track filter usage the Pre Filter and Filter Life Counters should be reset each time the filters are changed Refer to Changing the Pre Filter pg 10 or Changing th...

Page 9: ...cleaning These particles are also more easily captured by the HEPA filter as they pass through the HEPA Air Purification System To ensure the best air circulation in the room we recom mend that you p...

Page 10: ...at you should replace the pre filter To maintain proper odor removing capability and overall filtration performance the pre filter should be changed every 2000 hours approximately 3 months of use If n...

Page 11: ...or will flash refer to Filter Life Counters for additional information pg 8 This is a reminder that you should check the filter and replace if necessary The proper time to change the filter depends on...

Page 12: ...efer to Fig 12 Press the filter firmly into the air purifier To avoid damaging the filter media you should press on the frame of the filter only 5 Place the front grill back onto the unit First line u...

Page 13: ...00 4HUNTER for your nearest retailer or Hunter Customer Service at 1 800 313 3326 CAN 1 888 855 8300 to order directly To or der online visit our Website at www hunterfan com To ensure that you obtain...

Page 14: ...unit is plugged in Check the installation of the front grill Reset the air purifier See Resetting the Air Purifier on pg 9 Key pad has been locked to prevent accidental changes to the programs See Ke...

Page 15: ...ITNESS FORA PARTICULAR PURPOSE ARE VOIDED NO WARRANTY EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS MADE IN RESPECT TO THE FILTER MATERIAL OR CA...

Page 16: ...establishes proof of purchase IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR DIRECT INDI RECT SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE AIR PURIFIER YOUR S...

Page 17: ...w hunterfan com Other Home Comfort Products from Hunter The Care Free Humidifier Programmable Thermostat Hunter Original Fans HUNTER FAN COMPANY 2500 FRISCO AVENUE MEMPHIS TN 38114 USA 41791 01 Printe...

Reviews: