JINTDBW09 Rev B 05/03/15 

 
 
 

 
 
 
 
 
 
 
 
G

ENERAL 

G

UIDANCE

 

It  is  important  that  your  stove  is  correctly 
installed  and  operated  as  Hunter  Stoves  cannot 
accept responsibility for any fault arising through 
incorrect  installation,  use,  maintenance  or 
servicing. 
 
These  instructions  cover  the  basic  principles  to 
ensure  satisfactory  installation  of  the  stove, 
although  detail  may  need  slight  modification  to 
suit particular local site conditions.  
 
The installation must comply with current Building 
Regulations,  National  and  European  Standards, 
Local  Authority  Byelaws  and  other  specifications 
or regulations as they affect the installation of the 
appliance.  
 
The  Building  Regulations  requirements  may  also 
be 

met 

by 

adopting 

the 

relevant 

recommendations  in  the  current  issues  of  British 
Standards BS 8303 and BS EN 15287-1. 
 
Only  use  approved  fuels  on  this  appliance. 
Information about this can be found on Page 18. 
 
This  is  a  Domestic  Appliance  and  must  only  be 
used in accordance with these instructions. 
Do  not  place  articles  that  are  affected  by  high 
temperatures  on,  or  near,  this  appliance.  Do  not 
place  furniture  or  other  items  within  700mm  of 
the  front  of  this  appliance.  See  the  note  on 
material clearances on page 10. 
 

Extractor Fans and/or Cooker Hoods must not be 
installed  in  the  same  space  or  room  as  this  can 
cause the appliance to emit fumes into the room. 
 
Do  not  obstruct  the  ventilation  required  for  the 
safe use of this appliance. 
 

C

OMPETENT 

P

ERSONS 

S

CHEME

 

Hunter  Stoves  recommend  that  this  stove  is 
installed  by  a  member  of  an  accredited 
competent persons scheme e.g. HETAS. 
 
If  the  installer  is  not  a  member  of  a  competent 
person’s scheme, it is  a legal requirement, in the 
UK, to notify your Local Building Control Officer in 
advance of any installation work starting. 
 

H

EALTH AND 

S

AFETY 

P

RECAUTIONS

 

Special  care  must  be  taken  when  installing  the 
stove  such  that  the  requirements  of  the  Health 
and Safety at Work Act are met. 
 

H

ANDLING

 

This  appliance  is  very  heavy.  Adequate  facilities 
must  be  available  for  loading,  unloading  and  site 
handling 
 

F

IRE 

C

EMENT

 

Some types of fire cement are caustic and should 
not be allowed to come into contact with the skin. 
In case of contact, wash immediately with plenty 
of water.  

 
 

 

IMPORTANT INFORMATION 

PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION AND OPERATION. 

 

KEEP THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE AND SERVICING. 

 

THIS APPLIANCE WILL BECOME HOT WHEN USED IN ACCORDANCE WITH THESE INSTRUCTIONS. 

HUNTER STOVES RECOMMEND THAT AN APPROVED GUARD IS USED TO PROTECT THE YOUNG, 

ELDERLY OR INFIRM FROM HARM. 

 

THE INSTALLER COMMISSIONING SHEET CAN BE FOUND ON THE BACK COVER. 

PLEASE ENSURE THAT IT IS COMPLETED PRIOR TO USE. 

Summary of Contents for Telford Inset 20DB CVWSTI08DBFM

Page 1: ...JINTDBW09 Rev B 05 03 15 Telford Inset 20DB Multifuel Boiler Stove Model CVWSTI08DBFM CVWTI08DBFM Instructions for Installation Operating Maintenance Servicing...

Page 2: ...omponents and the use of un authorised fuels Consumables are deemed to be Glass Seals Gaskets Grate Components Log Retainers Baffles Thermostat and the surface finish of the appliance The Warranty wil...

Page 3: ...mission at 13 O2 0 33 Mean Flue Gas Temperature 385 C EFFICIENCY 69 9 Flue Gas Mass Flow 14 1g s Maximum operating water temperature in C 100 C Maximum operating pressure in bar 1 2 Bar Minimum cleara...

Page 4: ...ds must not be installed in the same space or room as this can cause the appliance to emit fumes into the room Do not obstruct the ventilation required for the safe use of this appliance COMPETENT PER...

Page 5: ...emit fumes Occasional fumes from de ashing and refueling may occur Persistent fume emission must not be tolerated This appliance should not be operated with the door open If fume emission does persis...

Page 6: ...r by lifting upwards of its supports and remove from firebox 3 Remove the fuel retainer support front plate by lifting the fuel retainer support clear from its locating slots Then remove 4 Remove the...

Page 7: ...ear grate bar support by lifting the grate bar support clear of the locating slots and remove 9 Remove the baffle by sliding it forward until it reaches its stop Then lift and slide forward until clea...

Page 8: ...onry and flue block chimneys must meet the requirements of Building Regulations Document J Any connecting flue pipe systems must also meet these regulations Please check the suitability of the firepla...

Page 9: ...are and attention to meet the requirements of the Health Safety code of practice and any other legislation that may have been introduced since the publication of these instructions COMPETENT PERSONS S...

Page 10: ...uld extend to at least 300mm in front of the stove and 150mm at the sides The constructional hearth should be made of solid non combustible material and can include any solid non combustible floor The...

Page 11: ...m Installing the Stove 1 Check positions of pipe connections 2 Make suitable access holes so you can access the tappings and infill with vermiculite concrete 3 Apply fire cement around the rope seal T...

Page 12: ...ed that a flue forming pipe short length of flue pipe is used and the void between the flue forming pipe and the chimney is filled with vermiculite concrete A suitable access hole will need to be made...

Page 13: ...o the cylinder The cylinder and heat leak radiator must be sited higher than the stove Semi pumped systems should be used on heating and hot water systems with gravity circulation to the hot water cyl...

Page 14: ...C Circulating Pump Low Limit Thermostat 45 C Time Switch Drain Cock Injector Tee Four Tapping System Two Tapping System Wiring Diagram for general guidance only All electrical work must be carried out...

Page 15: ...owly ensuring that no products of combustion enter into the room When the appliance has reached working temperature open the door move the Baffle to the re fuelling position see instructions on page 1...

Page 16: ...ws open AEROSOLS Do not use an aerosol spray on or near the stove when it is alight AIR CONTROLS This stove has been designed to burn cleaner and more efficiently than a conventional stove If used cor...

Page 17: ...ire bed and allow the fire to burn over the entire area of the grate The ashpan should be emptied at least daily and ash should never be allowed to build up over a period of time as this will result i...

Page 18: ...air and will die down If you want to revive the fire it is recommended that the thermostat control is opened first and then the secondary air control Warning The stove will remain hot for a considera...

Page 19: ...lace a glass panel please ensure you purchase a new Gasket at the same time Please check periodically that the glass clips and screws have not become loose GASKETS All gasket used on this appliance ar...

Page 20: ...flue system will cause poor performance of your appliance Excessive Flue Draught can cause low heat output Poor burning control excessive fuel consumption and even noise from the Air Controls Low Flu...

Page 21: ...B 05 03 15 Spares Information SINGLE DOOR SINGLE DOOR HCE09008 DOOR HANDLE ASSEMBLY TDI05ARRT011MB DOOR GLASS HCE09102 ROPE SEALING KIT SCPCB900SDRSK REVC GLASS GASKET HCE09101 GLASS CLIP HHR08046 SC...

Page 22: ...ASS HCE09031 ROPE SEALING SCPCB900DRSK GLASS GASKET HCE09030 GLASS CLIP HHR08046 SCREW FSJM05008SS RIGHT HAND DOOR HCE09009 DOOR HANDLE ASSEMBLY TDW09ARRT011MB GLASS CLIP HHR08046 SCREW FSJM05008SS GL...

Page 23: ...UPPER P112032 LOWER P112033 OPERATING TOOL HFR07040 FUEL RETAINER HCW09ARRT025 HINGE PIN FRRE08 1 75 HINGE HH06050 BRICK LEFT HCW09051A RIGHT HCW09051B SLIDER KNOB HCE05040M BAFFLE HCW09ARRT011 CAM B...

Page 24: ...NFORMATION Date Installed Appliance Stock Code Appliance Description Serial Number COMMISSIONING CHECK Complete Sign YES NO Does the chimney flue system meet the appropriate standard Has the chimney f...

Page 25: ...ervicing Company Engineer Signature 9th Service Date of Service Date of next Service Servicing Company Engineer Signature 2nd Service Date of Service Date of next Service Servicing Company Engineer Si...

Reviews: