background image

 RAC-510/511PE 

 

Standalone Access Controller 

Hardware Manual 

Version 1.0 

 
 

 

 

 
 

 

Summary of Contents for RAC-510PE

Page 1: ...RAC 510 511PE Standalone Access Controller Hardware Manual Version 1 0...

Page 2: ...ction 16 3 2 6 Slave Reader Connection 18 3 2 7 Power Supply Connection 19 Chapter 4 Installations 20 4 1 Hardware Setup 20 Chapter 5 Setting 21 5 1 ID Setting 21 5 2 Function Settings 22 5 2 1 Add a...

Page 3: ...er Code 42 5 2 21 Set Disarm Card Code 43 5 2 22 Set Duress Card Code 44 5 2 23 Set Memory Mode 45 5 2 24 Door Open Mode 46 5 2 25 Slave Reader Setting 47 5 2 26 System Initialization 48 Chapter 6 Tes...

Page 4: ...Chapter 1 Product Overview 1 1 Package Contents Controller x 1 Base x 1 Quick Start Guide x 1 Screw x 3 Cable x 1 HUNDURE 4 RAC 510 511PE Hardware manual...

Page 5: ...rammable unlock door duration z Casing tamper proof detection and door ajar alarm Programmable door sensor detection time z Duress card code setting When door opened in the emergency controller will s...

Page 6: ...ts 1024 800 LED Indicator Comm Keypad 12 Keys 0 9 Real Time Clock YES None Beep Tone Buzzer Communication Interface RS 485 None Communication Baud Rate 19200 bps N 8 1 None ID Setting DIP switch setti...

Page 7: ...Chapter 2 Physical Dimension 2 1 Dimension Scale mm HUNDURE 7 RAC 510 511PE Hardware manual...

Page 8: ...ce Introduction HUNDURE 8 RAC 510 511PE Hardware manual A Case Sensor B ID Settings C Kindly refer to the pin assignments below3 2 2 D Built in Relay When Electric Bolt Lock is used kindly connect the...

Page 9: ...and NC contacts When Electric Strikes Lock is used kindly connect the wire to COM and NO contacts HUNDURE 9 RAC 510 511PE Hardware manual...

Page 10: ...Chapter 3 System Configuration Wire Connections 3 1 System Configuration RAC 510 HUNDURE 10 RAC 510 511PE Hardware manual...

Page 11: ...RAC 511 HUNDURE 11 RAC 510 511PE Hardware manual...

Page 12: ...3 2 Wire Connections 3 2 1 Communication Interface Connection The device RAC 511 does not provide RS 485 functionality the wires colors are Yellow Blue HUNDURE 12 RAC 510 511PE Hardware manual...

Page 13: ...3 2 2 ACU 30 Wire Diagram The device RAC 511 does not provide RS 485 functionality the wires colors are Yellow Blue HUNDURE 13 RAC 510 511PE Hardware manual...

Page 14: ...3 2 3 Alarm Connection With ACU 30 for digital output HUNDURE 14 RAC 510 511PE Hardware manual...

Page 15: ...3 2 4 Electronic Lock Setup Without ACU 30 for digital output With ACU 30 for digital output HUNDURE 15 RAC 510 511PE Hardware manual...

Page 16: ...3 2 5 Exit Button Door Sensor Connection Without ACU 30 for digital output HUNDURE 16 RAC 510 511PE Hardware manual...

Page 17: ...With ACU 30 for digital output HUNDURE 17 RAC 510 511PE Hardware manual...

Page 18: ...3 2 6 Slave Reader Connection HUNDURE 18 RAC 510 511PE Hardware manual...

Page 19: ...3 2 7 Power Supply Connection Note To avoid interference self detection of sensitive keypad please do not touch keypad when input power HUNDURE 19 RAC 510 511PE Hardware manual...

Page 20: ...ck base onto the wall or other desired location B Connect the wires in accordance with the wiring instruction below C Make sure the back base and the controller upper cover guides are aligned D Instal...

Page 21: ...Chapter 5 Setting 5 1 ID Setting For RAC 510 only HUNDURE 21 RAC 510 511PE Hardware manual...

Page 22: ...pon entering command mode zController beeps five times and waits for the command input zPWR LED flashes red light zAfter entering command controller beeps once Input the parameter settings for the com...

Page 23: ...ressed or shared memory card number should be exactly 10 digits If you don t want to add password simply press zPasswords are not allowed under shared mode z Card number has not been given a password...

Page 24: ...a Card Number Command Code 02 Deletes a single card number and also removes its access authorization HUNDURE 24 RAC 510 511PE Hardware manual Enter 02 Input Card Number Completed Master Card Code Defa...

Page 25: ...numbers Deleting all card numbers will remove all access authorizations and requires user to input new card numbers Kindly take caution in performing this operation HUNDURE 25 RAC 510 511PE Hardware...

Page 26: ...ode 04 Successive Addition of Card Numbers RAC 510 511 allows user to add card numbers in an efficient manner by simply entering the index card number and the total number of cards to add HUNDURE 26 R...

Page 27: ...ed to be performed under shared memory Command Code 05 Successive deletion of card numbers All access authorizations will be deleted as well HUNDURE 27 RAC 510 511PE Hardware manual Enter 05 Initial C...

Page 28: ...Toggle z Pulse Door relay will return to original position within the time user set z Toggle Door relay will not return to original position until alarm relay has been activated again HUNDURE 28 RAC 5...

Page 29: ...or exit button request Default time is 4 sec Time duration can be set from 1 to 600 sec System ignores parameters set to 0 or greater than 600 sec default time is applied HUNDURE 29 RAC 510 511PE Har...

Page 30: ...system will monitor door s status If the allotted door open time has expired controller beeps every 0 5 sec The door has to be closed for the controller to terminate its alarm However if door was forc...

Page 31: ...9 sec to set conditional unlock door settings The door can remain open until the allotted time If parameter value is set to 0 then conditional unlock door function is deactivated HUNDURE 31 RAC 510 51...

Page 32: ...e compare valid address zCompare Valid address Compare valid code Index 1 X16 Compare valid code length z0 Select All zOnly support standard card mode HUNDURE 32 RAC 510 511PE Hardware manual Enter 13...

Page 33: ...Controller Beeps and Door Prop Alarm 2 Controller Beeps and Door Prop Alarm 2 0 Enable Forced Door Open Detection 0 Door Forced Detection 64 Disable Forced Door Open Detection 64 0 Enable Door Prop De...

Page 34: ...Disable Card Swipe 0 Card Swipe Identification 16 Enable Card Swipe 16 0 Keypad Tones OFF 0 Keypad Tones 32 Keypad Tones ON 32 0 Disable Case Sensor 0 Enable Case Sensor 128 Enable Case Sensor 128 Exa...

Page 35: ...d Code 22 Enables re swipe card check time This function restricts a card to be swiped twice under a specified time HUNDURE 35 RAC 510 511PE Hardware manual Enter 22 Duration Master Card Code Default...

Page 36: ...ngs Function Table Function Code Action Value 0 Exit Button NC 0 Exit Button NO NC 1 Exit Button NO 1 0 Door Sensor NO 0 Door Sensor NO NC 4 Door Sensor NC 4 Example Exit Button as NO Door Sensor as N...

Page 37: ...Master Code Command Code 24 Sets valid access authorization to Master Code Door opens when Master Code is entered HUNDURE 37 RAC 510 511PE Hardware manual Enter 24 Value Master Card Code Default 3019...

Page 38: ...mm dd ww where yy stands for year 00 63 mm stands for month 01 12 dd stands for date 01 31 and ww stands for week 01 07 For RAC 510 only z 01 for Monday 07 represents Sunday and so on HUNDURE 38 RAC 5...

Page 39: ...time on the LCD display Time format is hh mm ss where hh represents hour 00 23 mm for minutes 00 59 and ss for seconds 00 59 For RAC 510 only HUNDURE 39 RAC 510 511PE Hardware manual Enter 26 hh mm s...

Page 40: ...ter is set to 1 keypads are enabled Note Do not disable keypad when you don t have the Master Card Master Code is required to enter command mode hence disabling the keypads will lock you out of the co...

Page 41: ...31 Allows user to save invalid card number To record invalid card numbers set parameter to 1 to ignore set to 0 For RAC 510 only HUNDURE 41 RAC 510 511PE Hardware manual Enter 31 Value Master Card Cod...

Page 42: ...1000 To change kindly follow the instructions below and input the new 10 digit master code Whenever a device initialization has been performed master code will be restored back to it default 30191000...

Page 43: ...0000 To change kindly follow the instructions below and input the new 10 digit or less disarm code card Whenever a device initialization has been performed disarm code will be restored back to it def...

Page 44: ...0 To change kindly follow the instructions below and input the new 10 digit or less duress code card Whenever a device initialization has been performed duress code will be restored back to default 11...

Page 45: ...card nos with password and 1800 event records iii Shared memory supports 65536 card nos without password and 1800 event records 1 Under compressed and shared memory mode card number should be exactly...

Page 46: ...mode swipe card only swipe card or key in card No swipe card or key in card No password This function is only applicable when RAC 510 511 is used as an access controller HUNDURE 46 RAC 510 511PE Hard...

Page 47: ...le Anti 0 Disable Anti 4 Disable Anti 4 0 T1 T2 Interface 0 16 Wiegand 26 Interface 8 Digits 16 32 Wiegand 26 Interface 10 Digits 32 Interface 48 Wiegand 34Interface 10 Digits 48 Example Slave reader...

Page 48: ...ers to default settings After performing this function card number and parameter should be reset Initialization should be performed only when the ff occurs On the initial installation set the device s...

Page 49: ...eps upon valid card swipe and status LED lits green If invalid card was swiped the controller will sound three long beeps and status LED will lit red Step 5 Swipe a valid card to activate Door Relay D...

Page 50: ...mode using Master Code A Master code is required to enter the command code hence initialization has to be performed Kindly contact your dealer or customer representative for more information on the i...

Page 51: ...ccessive deletion of card no For shared mode only MASTER 05 Initial Card No Total no of cards Completed 09 Door Relay Mode Default 400 MASTER 09 Summation of the value listed below Completed 0 Pulse D...

Page 52: ...o Enable 128 Door Pro p Detection Disable 0 to Enable 21 Advanced Settings 2 For more information about this command click on the command code MASTER 21 Summation of the value listed below Completed 1...

Page 53: ...s Card Code Default 1190 MASTER 92 Card No Code Completed Max 10 digit 93 Set Memory Mode MASTER 93 Value 93 Completed 0 Standard Mode 1 Compressed Mode 2 Shared Mode 94 Door Open Mode For Access Cont...

Page 54: ...5M RS 485 Cable 4 core shielded twisted pair wire 20 22 AWG 800 M zUpgrade the cable specification according to transmission distance zUpgrade the cable specification as per environmental interference...

Page 55: ...ation or maintenance connection to improper equipment or attempted repair by anyone other than In no event shall manufacturer s liability exceed the price paid for the product from direct indirect spe...