3

USER INTERFACE

The 

L

EGEND

3000

User Interface is made up of the

following components: knobs and the LCD Display,
which in turn is made up of the RTS and the Chart
Windows.

Knobs

Four knobs on the 

L

EGEND

3000 S

ERIES

control all

user settings: M

ODE

, G

AIN

, C

ONTROL

P

ANEL

and R

ANGE

.

Mode Knob

The M

ODE

knob selects how the 

L

EGEND

3000 S

ERIES

locates the bottom and graphs the information on
the display. Turn the knob until the pointer aligns
with the desired mode of operation. See Modes of
Operation for more information.

Gain Knob

The G

AIN

knob controls the gain

(sometimes called sensitivity) of the
sonar receiver. Gain also powers the
unit on or off. When the 

L

EGEND

3000

S

ERIES

is off, press Gain to turn the

unit on. Press and hold Gain to turn
the unit off. Turn the Gain knob
clockwise to increase the gain; turn
counterclockwise to decrease the
gain. As you turn the knob, only new
sonar information being graphed
shows the effect of the gain change.

Increasing the gain shows faint sonar
returns from small bait fish and
suspended debris in the water, but
the display may become too
cluttered in some water conditions.
Increased gain is also beneficial at deeper depths to maintain a good
bottom image and show adequate sonar returns from deep objects.
Decreasing the gain eliminates the clutter from the display; however, if
adjusted too low, the display may not show many faint sonar returns that
could be fish.

Control Panel Knob

The C

ONTROL

P

ANEL

knob accesses features used to adjust some 

L

EGEND

3000 S

ERIES

settings. Push the knob to display the C

ONTROL

P

ANEL

list, then

rotate the knob to select a feature for adjustment. A light colored
background indicates the selected feature. Turn the R

ANGE

knob to adjust

the selected feature. Remove the C

ONTROL

P

ANEL

list from the display by

pushing the C

ONTROL

P

ANEL

knob again. If no adjustments are made after a

few seconds, the C

ONTROL

P

ANEL

list is removed automatically.

Range Knob

The R

ANGE

knob adjusts the depth ranges used on the display. The R

ANGE

knob has slightly different capabilities in each mode of operation. See
Modes of Operation for specific information. In all modes, turning the knob
clockwise increases the range, while turning it counterclockwise
decreases the range. Turning the knob slowly increases the adjustment in

small increments, while turning it quickly
makes large changes to the adjustment.

The LCD Display

The 

L

EGEND

3000 S

ERIES

uses a high-

resolution LCD display to show sonar
information, digital depth, temperature,
speed and other readouts.

A digital depth readout is always displayed
in the upper left corner of the LCD. When
the speed/temp accessory is connected,
additional digital readouts (such as MPH)
are shown below the depth. A voltage
readout appears in the bottom left when
the input voltage to the 

L

EGEND

3000

S

ERIES

is less than 11 volts or greater than

15 volts.

A depth range scale appears close to the
right side of the LCD display. This scale
indicates the distance from the surface of
the water to a depth range sufficient to
show the bottom. For example, in 18 feet of water, a 20 foot depth range
is selected. The depth range scale can be controlled automatically or
manually depending on the mode of operation. In A

UTOMATIC

and Bottom

Lock modes, the 

L

EGEND

3000 S

ERIES

selects the depth range. In M

ANUAL

mode, the depth range is selected by the user.

The sonar returns received by the 

L

EGEND

3000 S

ERIES

are displayed along

the depth range scale in a R

EAL

T

IME

S

ONAR

(RTS) W

INDOW

and

C

HART

W

INDOW

. The RTS W

INDOW

displays new sonar information
within the transducer cone in an
expanded, easy-to-see format;
the C

HART

W

INDOW

logs old RTS

W

INDOW

information to show a

contour view of the bottom and
structure.

Maximum Gain

Low Gain

Medium Gain

Depth Range
Scale

Depth, Temp and
Speed readouts

Real TIme Sonar™
Window

Chart
Window

USING THE LEGEND 3000 SERIES

USER INTERFACE / KNOBS / LCD DISPLAY

Summary of Contents for Legend 3000

Page 1: ...Operations Manual Operational instructions for Humminbird Legend 3000 Series including the Legend 3000 3005 3000 Deep and 3005 Deep...

Page 2: ...nbird com WARNING This device should not be used as a navigational aid to prevent collision grounding boat damage or personal injury When the boat is moving water depth may change too quickly to allow...

Page 3: ...oom Mode 8 Manual Mode 8 Chart Speed 9 Sonar View 9 Light 9 Contrast 9 RTS Window 9 Surface Clutter 10 White Line 10 Filter 10 Depth Alarm 10 Temp Alarm 11 Fish Alarm 11 Fish Sensitivity 11 Fish ID 11...

Page 4: ...b An audible chirp sounds as the unit turns on If the unit detects that the transducer is connected and is in water the LEGEND 3000 SERIES begins to show sonar information on the display If the transd...

Page 5: ...ts are made after a few seconds the CONTROL PANEL list is removed automatically Range Knob The RANGE knob adjusts the depth ranges used on the display The RANGE knob has slightly different capabilitie...

Page 6: ...S WINDOW can show the movement of the fish through the transducer beam Moving fish appear as smaller groups of lines that become progressively larger lines or vice versa A grouping of lines moving ver...

Page 7: ...When the boat and the fish are moving quickly relative to each other the fish creates a shorter arch A partial arch forms when the fish does not move through the entire cone angle Note It i s importan...

Page 8: ...ion currently selected for adjustment is indicated by a white background color 2 Rotate the CONTROL PANEL knob to select the desired option for adjustment Clockwise rotation selects options higher in...

Page 9: ...keep the bottom on screen The LEGEND 3000 SERIES uses a depth range to keep the bottom contour close to the bottom of the display To return the depth range to normal viewing turn the unit off and back...

Page 10: ...RIES continues to follow the bottom using the new range Any change made to the zoom preview bars is remembered until the LEGEND 3000 SERIES is powered off when the unit defaults to factory settings Ma...

Page 11: ...anually controlled except when the unit first powers up During initial power up the backlight turns on at full brightness so the display will be visible at night The backlight will then begin to decre...

Page 12: ...learly When a WHITE LINE setting of 1 to 8 is selected a light gray band highlights the strongest sonar returns within the sonar image and makes a distinctive outline along the bottom contour structur...

Page 13: ...n rises above it The outside temp alarm will sound when the water temperature was initially above the temp boundary and then falls below it The LOWER TEMP setting is retained in memory after the Legen...

Page 14: ...KTS displays depth in metres speed in nautical miles per hour FATHOMS KTS displays depth in fathoms speed in nautical miles per hour FATHOMS KPH displays depth in fathoms speed in kilometres per hour...

Page 15: ...nit Next inspect the transducer cable from end to end for breaks kinks or cuts in the outer casing of the cable and repair after disconnecting the cable from both the unit and the transducer Also make...

Page 16: ...t 15 38cm from the prop 10 The screen does not display a full fish arch Check the running angle of the transducer If the running angle is too great a full fish arch may not appear Reduce the running a...

Page 17: ...pair Authorization Number for your unit Please have your product model name and serial number available before calling the factory If you contact the factory by e mail please include your product mode...

Page 18: ...g Frequencies 50 200 kHz Power Output 4000 Watts Peak to Peak 500 Watts RMS Area of Coverage 20 and 74 at 10 dB Power Requirement 10 20 VDC Display 8 level FSTN Grayscale LCD LCD Matrix 160 H x 160 V...

Reviews: