background image

Bottom Lock Zoom Mode

B

TM

L

OCK

(Bottom Lock)

mode tracks the bottom
similarly to Automatic
mode; however, the
display shows a full
range view on right and
a zoomed window on
the left. The zoomed
window provides added
display resolution for
separating sonar returns
that are very close
together, such as those
caused by fish
suspended close to the
bottom. 

As the depth changes,
the 

L

EGEND

3000 S

ERIES

automatically keeps the
bottom visible in the
zoomed window and the
full range view. In the full
range view, horizontal
zoom preview bars
define the area of
bottom being enlarged.
The default setting
varies based on the
depth range; however,
this setting can be
changed to show more
area around the bottom,
or to show the bottom in greater detail. 

To change the area of the bottom being zoomed,
follow these steps:

1. Make sure the 

L

EGEND

3000 S

ERIES

is operating in 

B

TM

L

OCK

(Bottom Lock) mode.

2. Push the 

R

ANGE

knob. An adjustment indicator

appears by the lower zoom preview bar, indicating
this is the selected depth limit for adjustment.

Note: Pushing the R

ANGE

knob toggles between the upper and

lower zoom preview bar adjustment. If the lower zoom
preview bar is to be adjusted, push the R

ANGE

knob until it is

selected.

3. Rotate the 

R

ANGE

knob to adjust the zoom preview bar.

Moving the zoom preview bars closer together increases
the display resolution in the zoomed window; moving
them further apart decreases display resolution, but
allows more area around the bottom to be viewed. 

The indicators disappear after several seconds with
no adjustment. The 

L

EGEND

3000 S

ERIES

continues to follow

the bottom using the new range. Any change made to
the zoom preview bars is remembered until the 

L

EGEND

3000 S

ERIES

is powered off, when the unit defaults to

factory settings.

Manual Mode

M

ANUAL

mode turns off

automatic bottom tracking

,

leaving control of the
depth range to the user. Both the
upper and lower depth ranges
can be adjusted to show the
bottom, or any other desired
depth, in greater detail. When first
switched to 

M

ANUAL

mode, the 

L

EGEND

3000 S

ERIES

defaults to the current

automatic depth range; however,
after the manual depth ranges
have been set, the 

L

EGEND

3000 S

ERIES

uses the new settings until it is
powered off, when it defaults to
factory settings.

M

ANUAL

mode works best in areas

of relatively flat bottom or if you
are trolling slowly. It is also ideal
for displaying a small area of the
overall depth range in great detail
if you are looking for fish at a
specific depth. 

To adjust the depth ranges
manually, follow these steps:

1. Make sure the Legend 3000

Series is operating in Manual
mode.

2. Push the Range knob. An

adjustment indicator appears
at the location of the Lower
Depth Range, indicating that it
is ready for adjustment. 

Note: Pushing the Range knob toggles
between the upper and lower depth
range selection. If the Upper Depth
Range is to be adjusted, push the
Range knob until it is highlighted.

3. Rotate the 

R

ANGE

knob to adjust the Depth Range.

Clockwise rotation increases the depth;
counterclockwise rotation decreases the depth. The
display updates as the changes are made.

8

USING THE LEGEND 3000 SERIES

BOTTOM LOCK ZOOM MODE / MANUAL MODE

Manual Mode

Upper Depth Range
Adjustment Indicator

Lower Depth Range
Adjustment Indicator

Bottom Lock Zoom Mode

Zoom
Window

Zoom Preview
Bars

Adjustment Indicator

Summary of Contents for Legend 3000

Page 1: ...Operations Manual Operational instructions for Humminbird Legend 3000 Series including the Legend 3000 3005 3000 Deep and 3005 Deep...

Page 2: ...nbird com WARNING This device should not be used as a navigational aid to prevent collision grounding boat damage or personal injury When the boat is moving water depth may change too quickly to allow...

Page 3: ...oom Mode 8 Manual Mode 8 Chart Speed 9 Sonar View 9 Light 9 Contrast 9 RTS Window 9 Surface Clutter 10 White Line 10 Filter 10 Depth Alarm 10 Temp Alarm 11 Fish Alarm 11 Fish Sensitivity 11 Fish ID 11...

Page 4: ...b An audible chirp sounds as the unit turns on If the unit detects that the transducer is connected and is in water the LEGEND 3000 SERIES begins to show sonar information on the display If the transd...

Page 5: ...ts are made after a few seconds the CONTROL PANEL list is removed automatically Range Knob The RANGE knob adjusts the depth ranges used on the display The RANGE knob has slightly different capabilitie...

Page 6: ...S WINDOW can show the movement of the fish through the transducer beam Moving fish appear as smaller groups of lines that become progressively larger lines or vice versa A grouping of lines moving ver...

Page 7: ...When the boat and the fish are moving quickly relative to each other the fish creates a shorter arch A partial arch forms when the fish does not move through the entire cone angle Note It i s importan...

Page 8: ...ion currently selected for adjustment is indicated by a white background color 2 Rotate the CONTROL PANEL knob to select the desired option for adjustment Clockwise rotation selects options higher in...

Page 9: ...keep the bottom on screen The LEGEND 3000 SERIES uses a depth range to keep the bottom contour close to the bottom of the display To return the depth range to normal viewing turn the unit off and back...

Page 10: ...RIES continues to follow the bottom using the new range Any change made to the zoom preview bars is remembered until the LEGEND 3000 SERIES is powered off when the unit defaults to factory settings Ma...

Page 11: ...anually controlled except when the unit first powers up During initial power up the backlight turns on at full brightness so the display will be visible at night The backlight will then begin to decre...

Page 12: ...learly When a WHITE LINE setting of 1 to 8 is selected a light gray band highlights the strongest sonar returns within the sonar image and makes a distinctive outline along the bottom contour structur...

Page 13: ...n rises above it The outside temp alarm will sound when the water temperature was initially above the temp boundary and then falls below it The LOWER TEMP setting is retained in memory after the Legen...

Page 14: ...KTS displays depth in metres speed in nautical miles per hour FATHOMS KTS displays depth in fathoms speed in nautical miles per hour FATHOMS KPH displays depth in fathoms speed in kilometres per hour...

Page 15: ...nit Next inspect the transducer cable from end to end for breaks kinks or cuts in the outer casing of the cable and repair after disconnecting the cable from both the unit and the transducer Also make...

Page 16: ...t 15 38cm from the prop 10 The screen does not display a full fish arch Check the running angle of the transducer If the running angle is too great a full fish arch may not appear Reduce the running a...

Page 17: ...pair Authorization Number for your unit Please have your product model name and serial number available before calling the factory If you contact the factory by e mail please include your product mode...

Page 18: ...g Frequencies 50 200 kHz Power Output 4000 Watts Peak to Peak 500 Watts RMS Area of Coverage 20 and 74 at 10 dB Power Requirement 10 20 VDC Display 8 level FSTN Grayscale LCD LCD Matrix 160 H x 160 V...

Reviews: