Printer Station

The Printer Station connects the instrument to the mains voltage and also
provides power for the Reader Unit if it is docked (???). Sending measurement
data either to the printer or to a computer via serial port can be done the
following way: first, make sure the Reader Unit is connected to the Printer
Station. Data communication is executed through the infrared (IR) transmission
line: either docking the Reader Unit or placing it in a direct sight line with the
Printer Station. Test data of the previously selected memory range will be printed
out on the built in thermo-paper printer at a speed of 2 lines per sec.

Note: The printer will operate only if it is connected to mains.

4.8 

Serial Port

The 

COMBILYZER Plus

 serial communication protocol offers two options:

either the PC Unidirectional protocol, when upon a Start signal the selected data
of the test (measurement) is sent to the receiver computer, or Network protocol
can be used. the communication protocol can be selected in the
Menu/Setup/Serial submenu. By checking the Bl. ID field it can determined
whether the uploaded serial data should be identified by patient ID or by
sequence ID. In this submenu all serial data flow and the printer itself can be
disabled.

Note:

-

  Use only the serial port on the Reader Unit for uploading data to the host PC.

The serial port on the Printer Station is an input only for manufacturer
calibration.

-

  If the Enable field is unchecked, no test result will be printed out or sent

through serial port. In this case test results can only be viewed on the LCD.

-

  The PC unidirectional protocol does not apply control sum checking.

-

  When sending/uploading result data to a computer, the 

COMBILYZER Plus

needs to be connected to the host computer (PC) via the interface cable
(included) and the serial output line needs to be enabled.

Summary of Contents for COMBILYZER Plus

Page 1: ...o 17601P Human Gesellschaft f r Biochemica und Diagnostica mbH Max Planck Ring 21 D 65205 Wiesbaden Germany Telefon 49 6122 9988 0 Telefax 49 6122 9988 100 eMail human human de Internet http www human...

Page 2: ...the Image Processing Program 10 4 3 3 Setting Pad Sequence in the Printout 11 4 4 Service Menu Options Menu Service 12 4 4 1 Code Card 12 4 4 2 Selecting Measuring Mode 13 4 5 Measurement 13 4 5 1 Se...

Page 3: ...2 22 User Manual COMBILYZER Plus This page left blank...

Page 4: ...is within one minute by simple but careful observation The colour change occurring on each segment of the strip is compared to a colour chart to obtain the result However misreading or misinterpreting...

Page 5: ...s and evaluates the strips automatically The urine test strip containing chemical reagents is positioned under the reader s sensor After the pads colours have been evaluated the strip should be discar...

Page 6: ...d out by connecting the reader to the Printer Station The instrument is designed specifically for in vitro diagnostic professional use and to meet the requirements of medical professionals The measure...

Page 7: ...move the Reader Unit from its docked position locate its battery holder on the bottom remove the cover plate and load the batteries included as shown in figure 3 Reconnect the Reader Unit in its docke...

Page 8: ...reen the boot up process will continue Take a roll of printer paper and load it into the printer paper holder see fig 4 Insert the paper into the paper feeder slot and close the cover plate The printe...

Page 9: ...will return to main menu The OK button is used to enter the edited data and quit the function 4 2 Setup Procedure Menu Setup 4 2 1 Setting the Clock Select Menu Setup Clock in the menu to set date an...

Page 10: ...r unselecting the B1 ID identifies the result reports The standard mode setting is 9600 Baud 8 bits with 1 Stop bit and no parity Other options can not be programmed For more information on the serial...

Page 11: ...sensitivity Measurement sensitivity in the program can be adjusted on two levels in both directions for each pad In figure 7 the display shows the default setting for sensitivity The sensitivity chang...

Page 12: ...igure 8 Changing the pad sequence Pad names can be marked in the list on the right with the help of the UP and DOWN control buttons When the desired pad name is marked select it by pressing CHOOSE The...

Page 13: ...maximum number of measurements being allowed with the given code When opening a new vial of strips select the Menu Service Calibration submenu from the menu system Find the Calibration Card in the str...

Page 14: ...me is too short or too high false results my be obtained Refer also to the package insert of the COMBINA 11S test strips 4 5 Measurement 4 5 1 Setting Patient ID for Measurement A measurement can be i...

Page 15: ...will close again and the measuring cycle will start 7 From this step on the test process is controlled automatically by the COMBILYZER Plus if the Timer measuring mode has been previously selected se...

Page 16: ...elected limit can be adjusted with the help of the UP and DOWN arrows The lower limit can not be higher than the upper limit therefore increasing the low limit will increase the high limit and decreas...

Page 17: ...rint or the Memory Send submenu and choose a data record by adjusting the low limit of the memory range see figure 10 After pressing the Set ID button a new patient ID for the selected record can be s...

Page 18: ...Unidirectional protocol when upon a Start signal the selected data of the test measurement is sent to the receiver computer or Network protocol can be used the communication protocol can be selected i...

Page 19: ...ttery recharge The COMBILYZER Plus s portable Reader Unit is powered by 3 AA size rechargeable batteries Their fully charged capacity is sufficient for about 300 test measurements sufficient for about...

Page 20: ...Memory is full clear some memory addresses 3 Battery low recharge the batteries 4 Netw comm error check the serial com synchronisation 5 Serial disabled enable the serial output 6 There is no strip l...

Page 21: ...en LCD Printer 57 mm thermal printer 2 lines sec Size 480 x 290 x 165 mm Weight 850 g External power adapter 7 5 V DC 1 5A Interfaces RS232 serial port Op temperature 15 30 C Relative humidity 20 80 8...

Page 22: ...User Manual COMBILYZER Plus 21 22 9 SYMBOLS according to EN 980 In vitro diagnostic medical device Warning Information inside Serial number Manufacturer SN...

Page 23: ...22 22 User Manual COMBILYZER Plus 10APPENDIX The Menu Structure...

Page 24: ...o 17601P Human Gesellschaft f r Biochemica und Diagnostica mbH Max Planck Ring 21 D 65205 Wiesbaden Germany Telefon 49 6122 9988 0 Telefax 49 6122 9988 100 eMail human human de Internet http www human...

Reviews: