Lubrication
The saw unit should be lubricated every 8 to 200 hours of
operation depending on the conditions that the unit is
working under. The unit has 2 lubrication points as shown
here.
See ill. 29.
Note!
Use a mineral oil based grease thickened with,
or mixable with a lithium soap. The grease should be
classified as L-XCCIB2 according to ISO 6743-9.
Molybdendisulfid content max 3 %. Base fluid
viscosity 170 to 220 cSt at 40°C. NLGI class 1-2.
The first month of operation
Fasteners
Tightening of the all fastners should be made once a week
during the first month of operation.
ill. 29
Lubrication points
1.
Feed out rack, 1 pcs.
2.
Bearing, 1 pcs.
1