background image

Declaration of Compliance

20

21

19

  1. 

HULK Professional HU6525 / HU6540 DC-DC Chargers

 is designed for charging one 100-1000Ah 12V Standard 

Automotive Lead-Acid, GEL, AGM, Calcium, SLI, Deep Cycle type or one 25-1000Ah Lithium rechargeable battery. 

The charger is not intended to supply power to a low voltage electrical system other than to charge a battery. 

Do not

 use it for any other purpose.

  

  2. 

DO NOT

 ATTEMPT TO CHARGE A NON-RECHARGEABLE BATTERY (PRIMARY CELLS). They may burst 

and cause injury to people and damage to property.

 

  3. 

Never 

charge a frozen battery. Never charge a damaged battery.

 

  4. 

Explosion hazard! 

A battery being charged could emit explosive gasses. Avoid smoking or open sparks or flames 

near the battery. Explosive and flammable substances such as fuel or solvents should not be kept near the 

charger or the battery.

 

  5. 

Danger of chemical burns!

 Battery acid is highly corrosive. If your skin or eyes are exposed to acid, immediately 

rinse the affected part of the body with excessive water and seek medical advice. 

 

  6. 

DO NOT

 alter or disassemble the Battery Charger under any circumstances, incorrect reassembly may result in 

electric shock or fire. Unauthorized disassembly, repairs or modifications will void the official warranty.

 

  7. 

Never

 place the charger above the battery being charged, gases from battery will corrode and damage the charger.

 

  8. During charging, batteries must be placed in a well ventilated area.

 

  9. Children or people with reduced physical, sensory or mental capabilities or lack of experience and knowledge 

should not use this appliance.

Congratulations on your purchase of the 

HULK Professional HU6525 / HU6540 DC-DC Charger

 7-Step 

fully automatic switch-mode battery charger, designed for charging a variety of lead-acid rechargeable & Lithium 

auxiliary batteries by providing a proprietary algorithm to each specific battery type.

 

HU6525 / HU6540

 chargers include all the features needed to achieve and maintain the auxiliary battery 

to its optimum condition at all times. 

HU6525 / HU6540 

chargers also feature MPPT (Maximum Power Point 

Tracking) solar regulator technology, allowing you to deliver maximum amount of power from the solar panels 

to the auxiliary battery.

Safety Information

1m
2m
3m
4m
5m

4 mm

2

7 mm

2

10 mm

2

13 mm

2

16 mm

2

5 mm

2

10 mm

2

15 mm

2

20 mm

2

25 mm

2

Note:

Please tighten the screws properly and 

ensure that none of the screws are 

loose. Max torque is 3N.m for the M5 

screws and 8N.m for the nuts.

A.

  Connect one end of the common ground cable to the “GND” terminal of the charger.

B.

  Connect the grounds of solar panel, vehicle starter battery, DC input (

for HU6540 only

) and Auxiliary battery

     to the other end of the common ground cable.

C.

  Connect one end of the auxiliary battery output cable to the “AUX” terminal. 

D.

  Connect the other end of the auxiliary battery output cable to the positive post of the auxiliary battery. 

     Insert an inline midifuse holder (P/N FU6061) and 60A fuse near the Auxiliary battery.

E.

  At this point, “OK/ERROR” LED should turn GREEN if the auxiliary battery voltage is within the charging 

range and default “AGM/GEL” battery is selected. 

F.

  Connect one end of the alternator input cable to the “ALT” terminal of the charger.

G.

 Connect the other end of the alternator input cable to the positive post of the Main battery. Insert an inline 

60A fuse near the Main battery.

H.

  At this point, “ALT” LED should turn-on if the alternator voltage is within the acceptable range. 

I.

   Connect one end of the solar input cable (if available) to the “SOLAR” terminal of the charger.

J.

  Connect the other end of the solar input cable to the positive output of the solar panel. 

K.

  At this point, “SOLAR” LED should turn-on if the solar voltage is within the acceptable range. 

L.

  Connect one end of the DC input cable (if available) to the “DC” terminal of the charger (

for HU6540 only

).

M.

 Connect the other end of the DC input cable to the positive output of the DC supply. Insert an inline 60A 

fuse for additional protection from short circuit i.e. cables touching the chassis (

for HU6540 only

).

N.

  At this point, “DC” LED should turn-on if the DC voltage is within the acceptable range. 

O.

  “CHARGE” LED will begin blinking to indicate if charging is in progress. 

Index

Electrical Specifications

Selecting Battery Type

Automatic Input Selection 

Removing the Cover

Parts of the Charger

 No external relays needed.

 

 By default, when there are multiple inputs 

available, the charger chooses which input 
should be active according to priority.

 

   

1. 

Alternator linked to starter battery

 

   

2. 

Unregulated solar power using built-in  

    Maximum Power Point Tracking 

(MPPT)

 

    Solar Controller

 

   

3.

 

DC Supply 

(HU6540 only)

 

 

HU6540

 has one more input terminal for DC 

voltage source i.e. ACDC power supply, 
wind turbines, etc. The charger tracks and 
utilizes the power capacity of the source.

In order to access the charger terminal, select the battery type and to 

install the temperature compensation & ignition over-ride cables, the 

top cover needs to be removed.

 

Loosen the two screws as indicated to release the cover.

1    Top Cover
2    Status Membrane
3    Remote Monitor Port
4    Metal housing
5    Mounting Feet
6    Solar Terminal
7    Alternator Terminal
8    Common Ground Terminal
9    Ignition Override Terminal
10  Temperature Sensor Terminal
11  Auxiliary Battery Terminal
12  Terminal Block

Product Package Contents 

HU6525

 or 

HU6540

 Battery Charger

Battery Temperature Sensor 3.5m cable
Ignition Sensor M3 Ring Terminal
Remote Display 

HU6526

 (optional)

User’s Manual

HU6525

 or 

HU6540

 Terminal Block (optional)

Ferrite Clamp (for 

HU6540

 only)

Mounting Screws

Wire Size Recommendation

Use the recommended minimum cable cross 

section area (mm2) to avoid significant voltage 

drop (approx. 0.35V). Note: Radiated Emission 

was tested using 1m cable.

Mounting the Charger 

Connecting the Charger

1.

 The charger can operate in harsh environments but 

it is best to locate far away from heat sources and 

excessive vibrations; and close to the auxiliary 

battery. It can be installed in any position, vertically 

or horizontally. 

2.

 Use the four mounting feet of the charger to attach 

to a secure flat surface.

3.

 Drill the four fixing holes and use the screws 

included in the package to fasten the unit.

4.

 Remove the top cover before wiring the charger. 

Put the top cover back after wiring for protection 

of the terminals.

     Item

AGM/Gel

Wet

Ca+

Li-ion

OK/Error

OK/Error

Alternator

Solar

DC (DX-40)

Charge

Charge

Float

Float

       LED

ON: 

Blue

ON: 

Blue

ON: 

Blue

ON: 

Blue

ON: 

Green

ON: 

Red

ON: 

Yellow

ON: 

Yellow

ON: 

Yellow

Blinking: 

Blue

ON: 

Blue

Blinking: 

Blue

ON: 

Blue

                 Indication

Battery Type Selection (default)

Battery Type Selection

Battery Type Selection

Battery Type Selection

Battery OK.

Battery Bad/Charging Error/Fault

Active Input Indication

Active Input Indication

Active Input Indication

Bulk Charging Stage

Absorption Charging Stage

Battery Analysis

Float Stage

Note:

Please tighten the screws 

properly and ensure that none 

of the screws are loose. Max 

torque is 3 N.m for the M5 

screws and 8 N.m for the nuts.

+

-

Connecting the Charger using the Terminal Block 

A,

B,

C,

D,

E,

F,

G,

H,

I,

J,

K,

L,

M,

N,

O,

P,

Q,

R,

Connect the matching terminal block to the charger and properly fasten the screws attaching the terminal 

block to the charger.

Flip the terminal block cover to access the ports for the cables.

Connect all the ground cables to any of the “GND” ports of the terminal block.

Connect the other end of the ground cables to each of the grounds of main battery, solar panel, DC input 

(

for HU6540 only

), and auxiliary battery.

Connect one end of the auxiliary battery output cable to the “AUX” port of the terminal block.

Connect the other end of the auxiliary battery output cable to the positive post of the auxiliary battery. 

Insert an inline midifuse holder (P/N FU6061) and 60A fuse near the auxiliary battery.

At this point, “OK/ERROR” LED should turn to GREEN if the auxiliary battery voltage is within the charging 

range and default “AGM/GEL” battery is selected.

Connect one end of the alternator input cable to the “ALT” port of the terminal block.

Connect the other end of the alternator input cable to the positive post of the main battery. Insert an inline 

midifuse holder (P/N FU6061) and 60A fuse near the main battery.

At this point, “ALT” LED should turn-on if the alternator voltage is within the acceptable range.

Connect one end of the solar input cable (if available) to the “SOLAR” port of the terminal block.

Connect the other end of the solar input cable to the positive output of the solar panel. 

At this point, “SOLAR” LED should turn-on if the solar voltage is within the acceptable range. 

Connect one end of the DC input cable (if available) to the “DC” port of the terminal block (

for HU6540 only

).

Connect the other end of the DC input cable to the positive output of the DC supply. Insert an inline 60A 

fuse for additional protection from short circuit i.e. cables touching the chassis (

for HU6540 only

).

At this point, “DC” LED should turn-on if the DC voltage is within the acceptable range. 

“CHARGE” LED will begin blinking to indicate if charging is in progress.

Close and latch the terminal block cover to protect the ports.

Temperature Sensor and Ignition Sensor Connection

Ignition

Temperature sensor

Temperature Sensor Installation

Ignition Sensor Installation 

Ignition sensor is another optional feature used to detect vehicle ignition 

and identify that the vehicle is running. This ignition connection enables a 

“low input operation” mode for compatibility with smart (variable voltage) 

alternators found in modern vehicles.

HU6525 / HU6540

 supports vehicles operating with 

24V alternators. These vehicles usually have two 

12V main batteries connected in series. The output 

of 

HU6525 / HU6540

 will charge 12V auxiliary 

battery or battery bank.

An AC powered battery charger can be connected

to the auxiliary battery without disconnecting the 

HU6525 / HU6540

 if it is in standby mode and not 

in any charging cycle.

The 

HULK HU6526

 Monochrome LCD display 

monitors the charging status of 

HU6525 / HU6540

The unit monitors voltage, current, state of charge 

and any warnings related to the charging.

Temperature sensor is an optional feature used to compensate for the 

auxiliary battery temperature and protect the battery from overheating. 

1.

 Cut a desired length of cable (recommended AWG22) and crimp to 

the M3 ring terminal included with the package to make the Ignition 

Sensor cable. 

2.

 Connect the ring terminal end of the Ignition cable to the “IGN” terminal 

of the charger.

3.

 Connect the sensor end of the Ignition cable to the ignition wiring of 

the vehicle.

1.

 Connect the ground of the Temp Sensor cable to the “GND” terminal 

of the charger.

2.

 Connect positive of the Temp Sensor cable to the “Sensor” terminal 

of the charger.

3.

 Connect the sensor end of the Temp Sensor cable to the negative pole 

of the Auxiliary battery.

1

 -  

Power:

 Single press toggles the display to 

standby mode or active mode.

2

 -  

Mode:

 Single press toggles the display 

mode from three choices.

3

 -  

Brightness Up:

 There are five levels of 

backlight brightness. Default is maximum level. 

Each single press will increase the brightness 

by one level up to the maximum level.

4

 -  

Brightness Down:

 There are five levels of 

backlight brightness. Default is maximum level. 

Each single press will reduce the brightness 

by one level down to minimum level.

a)

 

Active Input Source:

 The charger automatically chooses which 

input to use depending on the current condition. Shows STBY 

if not charging.

 

b)

 

Input Voltage:

 Actual voltage level of the active input source.

 

c)

 

Output Current:

 Actual current level that is being charged to  

the auxiliary battery.

 

d)

 

Output Voltage:

 Actual voltage level of the auxiliary battery.

 

e)

 

Battery Temperature:

 The temperature of auxiliary battery.

 

 f)

 

Battery Type:

 The type of auxiliary battery selected 

(AGM/Gel, Wet, Calcium, Li-ion).

 

g)

 

Percentage of Charge:

 Actual level of charge of the main 

and auxiliary battery shown as graphs.

1.

 Choose an appropriate location for mounting the monitor. 

It should be visible enough to see while driving.

2.

 Fix the wall mount using screws or double-sided adhesive tape. 

Wall mount fixture enables adjusting the monitor for better 

viewing angle. 

3.

 Attach the monitor housing to the wall mount fixture by fitting 

the ball joint stick to the slot at the back of the monitor and 

sliding it to lock.

4.

 Connect the USB Type-C end of the monitor cable to the  

HU6526

 USB connector slot. Gently push the cable plug into 

the display mating connector until it clicks into position.

5.

 Connect the other end of the monitor cable to the 

HU6525 / HU6540

 

6-pin connector slot. Follow the marking on the cable plug and 

mating connector for correct orientation. Gently push the cable 

plug into the display mating connector until it clicks into position.

6.

 At this point, display icons should be visible in the screen if the 

charger is powered. 

7.

 Press the Power button to toggle the monitor from standby 

mode and operating mode.

8.

 To disconnect Data Cable from the charger, apply little pressure 

on the sides of the Data Cable plug and slowly pull it back. 

HU6526 Remote Display

Remote Display Interface

Trouble Shooting

Remote Display Warning Messages

Remote Display Installation

a)

        

– Low Voltage Warning or Battery not connected.

 The main or Auxiliary battery voltage is lower than 11.4V 

or there is no connection to one of the batteries. Fuses and connections must be checked.

b) Flashing Voltage with

        – Battery won't hold charge.

c)

 

OVP – Over Voltage Protection.

 High voltage is detected at any of the SOLAR, ALT, AUX or DC terminals.

d)

 

OCP – Over Current Protection.

 The detected charge current is higher than specifications. Check short 

circuits or cable faults and then reset the whole system.

e)

 

OTP – Over Temperature Protection.

 Charging is suspended to prevent damage to the battery when the 

detected battery temperature is above 50ºC. Charger also stops if internal temperature is above 115ºC. 
The device will resume charging once temperature drops to a safe level.

 f)

 

REV – Reverse Polarity Protection.

 The auxiliary battery connection is reversed. Check the connection.

g)

 

BAD – 

Battery can’t be recovered.

 The charger has detected that the auxiliary battery is unable to be charged 

safely. Inspect the battery, replace if necessary.

HU6540

Li-ion

Wet

OK /

Float

DC

Ca

+

AGM/Gel

Battery

Charge

HU6525

Li-ion

Wet

OK /

Float

Ca

+

AGM/Gel

Battery

Charge

Keep this manual in a safe place for future reference.

For Your Safety

HU6526 Dimensions

Additional Applications

Do not operate the battery charger unless you have read and understood this manual and installed the charger 

as per instructions.

Safety Information

.....................................................................................................................

3

Product Package Contents

.......................................................................................................

4

Wire Size Recommendation

.....................................................................................................

4

LED Indications

.........................................................................................................................

5

Automatic Input Selection

........................................................................................................

6

Removing the Cover

.................................................................................................................

7

Parts of the Charger

..................................................................................................................

7

Mounting the Charger

...............................................................................................................

8

Connecting the Charger

............................................................................................................

9

Connecting the Charger using the Terminal Block

...............................................................

11

Temperature Sensor and Ignition Sensor Connection

.........................................................

13

  

Ignition Sensor Installation..................................................................................................

14

  

Temperature Sensor Installation..........................................................................................

14

HU6526 Remote Display

............................................................................................................

15

  

Remote Display Installation..................................................................................................

16

  

Remote Display Interface.....................................................................................................

17

  

Remote Display Warning Messages....................................................................................

18

Trouble Shooting

......................................................................................................................

19

Electrical Specifications

..........................................................................................................

21

Charging Algorithm

.................................................................................................................

22

Applications

.............................................................................................................................

23

Dimensions

..............................................................................................................................

25

25A

40A

22

24

23

25

26

6

AC

Battery

Charger

24V

12V

24V vehicles

Trailer or Caravan Installation

External battery charger connection

Important information is displayed in real time. Warning 

messages also appear if there is an abnormal condition.

                                                Output

Voltage                              
Current                              
Power      
Operating Temp  
Protection Class
Standard         
Dimension (mm)     
Weight (g)                                            800                      1140
Remote Display                                              Optional

Battery Type                               Bulk Voltage            Float Voltage

AGM / Gel
Standard Wet
Calcium
Lithium-Ion

max.

max.

max.

max.

                                                 DC Input

Low Voltage Turn OFF
Low Voltage Turn ON
Over Voltage Turn ON
Over Voltage Turn OFF

For safety reasons, the battery type can only be selected when the auxiliary battery is not connected, 

“OK/ERROR” LED is RED.

Press the “Battery” button to select the correct auxiliary battery type to be charged (AGM/Gel, 

Standard Wet, Calcium, and Lithium-Ion). 

    

Replacing the Battery

    Remove the connections of all the input sources before disconnecting the battery.

                                              Input Range

Alternator
Solar
DC 

                                             Solar MPPT    

12V Panel
18V Panel
24V Panel

                                      12V Alternator Input

Low Voltage Turn OFF
Low Voltage Turn ON
Over Voltage Turn ON
Over Voltage Turn OFF

                                      24V Alternator Input

Low Voltage Turn OFF
Low Voltage Turn ON
Over Voltage Turn ON
Over Voltage Turn OFF

                                        Ignition Override

Low Voltage Turn OFF
Low Voltage Turn ON
Over Voltage Turn ON
Over Voltage Turn OFF

max.

max.

max.

max.

max.

max.

Using the Ferrite Ring (HU6540 only)

For optimum EMI 

results, put the 

pair of input 

cables through 

the ferrite as per 

below diagram.

Standard Applications

Multiple Auxiliary Batteries

HU6540 Dimensions

HU6525 Dimensions

Summary of Contents for HU6525

Page 1: ...1 User Manual Dual Battery System Solar Charger In Vehicle DC DC Charger HU6525 HU6540 12 24V Alerntor 11 32V Max Temperature 85º C Max Current 25A 40A Solar MPPT 12 18 24V ...

Page 2: ...rs include all the features needed to achieve and maintain the auxiliary battery to its optimum condition at all times HU6525 HU6540 chargers also feature MPPT Maximum Power Point Tracking solar regulator technology allowing you to deliver maximum amount of power from the solar panels to the auxiliary battery Keep this manual in a safe place for future reference For Your Safety Do not operate the ...

Page 3: ...the Charger 9 Connecting the Charger using the Terminal Block 11 Temperature Sensor and Ignition Sensor Connection 13 Ignition Sensor Installation 14 Temperature Sensor Installation 14 HU6526 Remote Display 15 Remote Display Installation 16 Remote Display Interface 17 Remote Display Warning Messages 18 Trouble Shooting 19 Electrical Specifications 21 Charging Algorithm 22 Applications 23 Dimension...

Page 4: ...attery Explosive and flammable substances such as fuel or solvents should not be kept near the charger or the battery 5 Danger of chemical burns Battery acid is highly corrosive If your skin or eyes are exposed to acid immediately rinse the affected part of the body with excessive water and seek medical advice 6 DO NOT alter or disassemble the Battery Charger under any circumstances incorrect reas...

Page 5: ...6 optional User s Manual HU6525 or HU6540 Terminal Block optional Ferrite Clamp for HU6540 only Mounting Screws Wire Size Recommendation Use the recommended minimum cable cross section area mm2 to avoid significant voltage drop approx 0 35V Note Radiated Emission was tested using 1m cable 25A 40A Using the Ferrite Ring HU6540 only For optimum EMI results put the pair of input cables through the fe...

Page 6: ...dication Battery Type Selection default Battery Type Selection Battery Type Selection Battery Type Selection Battery OK Battery Bad Charging Error Fault Active Input Indication Active Input Indication Active Input Indication Bulk Charging Stage Absorption Charging Stage Battery Analysis Float Stage HU6540 Li ion Wet OK Float DC Ca AGM Gel Battery Charge HU6525 Li ion Wet OK Float Ca AGM Gel Batter...

Page 7: ...active according to priority 1 Alternator linked to starter battery 2 Unregulated solar power using built in Maximum Power Point Tracking MPPT Solar Controller 3 DC Supply HU6540 only HU6540 has one more input terminal for DC voltage source i e ACDC power supply wind turbines etc The charger tracks and utilizes the power capacity of the source 6 ...

Page 8: ...er ride cables the top cover needs to be removed Loosen the two screws as indicated to release the cover 1 Top Cover 2 Status Membrane 3 Remote Monitor Port 4 Metal housing 5 Mounting Feet 6 Solar Terminal 7 Alternator Terminal 8 Common Ground Terminal 9 Ignition Override Terminal 10 Temperature Sensor Terminal 11 Auxiliary Battery Terminal 12 Terminal Block ...

Page 9: ...iliary battery It can be installed in any position vertically or horizontally 2 Use the four mounting feet of the charger to attach to a secure flat surface 3 Drill the four fixing holes and use the screws included in the package to fasten the unit 4 Remove the top cover before wiring the charger Put the top cover back after wiring for protection of the terminals 8 ...

Page 10: ......

Page 11: ...nator input cable to the positive post of the Main battery Insert an inline 60A fuse near the Main battery H At this point ALT LED should turn on if the alternator voltage is within the acceptable range I Connect one end of the solar input cable if available to the SOLAR terminal of the charger J Connect the other end of the solar input cable to the positive output of the solar panel K At this poi...

Page 12: ...Note Please tighten the screws properly and ensure that none of the screws are loose Max torque is 3 N m for the M5 screws and 8 N m for the nuts Connecting the Charger using the Terminal Block 11 ...

Page 13: ......

Page 14: ......

Page 15: ...e and protect the battery from overheating 1 Cut a desired length of cable recommended AWG22 and crimp to the M3 ring terminal included with the package to make the Ignition Sensor cable 2 Connect the ring terminal end of the Ignition cable to the IGN terminal of the charger 3 Connect the sensor end of the Ignition cable to the ignition wiring of the vehicle 1 Connect the ground of the Temp Sensor...

Page 16: ......

Page 17: ...Gently push the cable plug into the display mating connector until it clicks into position 5 Connect the other end of the monitor cable to the HU6525 HU6540 6 pin connector slot Follow the marking on the cable plug and mating connector for correct orientation Gently push the cable plug into the display mating connector until it clicks into position 6 At this point display icons should be visible i...

Page 18: ......

Page 19: ...ent is higher than specifications Check short circuits or cable faults and then reset the whole system e OTP Over Temperature Protection Charging is suspended to prevent damage to the battery when the detected battery temperature is above 50ºC Charger also stops if internal temperature is above 115ºC The device will resume charging once temperature drops to a safe level f REV Reverse Polarity Prot...

Page 20: ......

Page 21: ...20 ...

Page 22: ...n OFF Low Voltage Turn ON Over Voltage Turn ON Over Voltage Turn OFF Input Range Alternator Solar DC Solar MPPT 12V Panel 18V Panel 24V Panel 12V Alternator Input Low Voltage Turn OFF Low Voltage Turn ON Over Voltage Turn ON Over Voltage Turn OFF 24V Alternator Input Low Voltage Turn OFF Low Voltage Turn ON Over Voltage Turn ON Over Voltage Turn OFF Ignition Override Low Voltage Turn OFF Low Volta...

Page 23: ......

Page 24: ...23 Trailer or Caravan Installation Standard Applications Multiple Auxiliary Batteries ...

Page 25: ......

Page 26: ...25 ...

Page 27: ...26 HU6540 Dimensions 178mm 59mm 128mm 138mm 160mm 123mm ...

Page 28: ...19 19 82 70 46 60 40 Tested and approved by and conforms to EN 60335 1 EN 60335 2 29 EN 55014 1 EN 55014 2 PAH Testing RoHS 2 0 IP67 Manufactured and Packaged for Automotive Imports Pty Ltd 22 28 Lexton Road Box Hill Victoria Australia Made in China AUS www hulk4x4 com au NZ www hulk4x4 co nz ...

Reviews: