background image

 

 

 
 

 

 

 
 
 
 
 
 
 
 
 

4.

 

Remove upper half of housing to 
reveal inside of fogger. 

 

 

 
 

 

 
 
 
 
5.

 

Using needle nose pliers, open 
ignitor crimp while holding structure 
firmly in place. 

 
 

 

 

 

6.

 

Lift out old ignitor and replace with new ignitor. 
Ignitor tip should be within 1/8 inch of coils. 
Retighten crimp while holding ignitor firmly in 
place. 

 

 
 

Summary of Contents for Fog 62691

Page 1: ...ough before trying to use fogger for the first time If you do not understand something please call the number below Hudson Model 62691 H D HUDSON MANUFACTURING COMPANY Hastings MN 55033 1142 1 800 9 S...

Page 2: ...is a Trigger This feature controls when the fog is released from the Fogger By pumping this Trigger the insecticide is turned into fog 5 Trigger Lock This button is located on the top front of the Fog...

Page 3: ...Always make sure that the Fogger is placed on a level surface to ignite and preheat 3 Open propane fuel valve no more than a 1 4 turn counter clockwise 4 Push in the ignitor button to initiate a spar...

Page 4: ...the wetness or dryness of the fog We recommend that you pump the Fogger every 3 to 4 seconds to achieve maximum effect A dry fog is always recommended The fog should be white in color If it appears b...

Page 5: ...te the Fogger only in well ventilated areas Always keep the Fogger away from flammable materials Do not smoke while filling and operating unit Do not fog near uncovered foodstuffs cooking and eating u...

Page 6: ...Remove Insecticide Vessel With fogger on its side carefully remove Plastic Pump Assembly Cover be aware of spring bearing inside cover from fogger Insert a small wire into hole in bottom of Pump Asse...

Page 7: ...f Flame will stop after excess insecticide is eliminated Piezo ignitor will not spark Ignitor broken or worn out Replace ignitor DIAGRAM SPARE PARTS AND FACTORY SERVICE If problems persist or you need...

Page 8: ...urrent plus 5 00 shipping and handling CONTACT INFORMATION 1 800 9 SPRAYER 1 800 977 7293 Instructions for replacing the Piezo Ignitor 1 Remove retainer screws 2 from each side of heat shield then rem...

Page 9: ...of fogger 5 Using needle nose pliers open ignitor crimp while holding structure firmly in place 6 Lift out old ignitor and replace with new ignitor Ignitor tip should be within 1 8 inch of coils Retig...

Page 10: ...attached to pump handle 8 Replace blue ignitor button cap on ignitor NOTE brass round points downward black square points upward 9 Place upper housing over assembly unit until halves line up and igni...

Page 11: ...r been damaged in shipment or mishap or which has been modified or repaired by unauthorized persons or been used in a manner inconsistent with manufacturer directions This warranty only applies to pro...

Page 12: ...THANK YOU FOR PURCHASING A HUDSON FOGGER For best results use Hudson Fog Mosquito and Flying Insect Killer Available in Convenient Economical 1 2 Gallon Size Ask for Hudson Item 62692FG...

Page 13: ...Volume mist hangs in the area and covers a wide area economically Ideal for mosquito control eliminating smoke odors protecting against plant disease etc When used indoors mist penetrates cracks and...

Reviews: