5.4
Mounting preparations
1.
Ensure all accessories are available (please refer to Chapter 10 Dimension drawings).
NOTES!
Fastening screws and earth cable are not included in the range of supply.
2. Preparing the place of attachment: Clean the (motor) shaft, centering, bolting surfaces and
fastening threads; check for damage. Repair any damage!
5.5
Mounting hollow-shaft type FGH 40
1.
Mount adapter shaft (1) and align using dial gauge.
NOTES!
The maximum radial run-out of the adapter shaft is 0.05 mm.
If necessary, use the ball thrust adjustment screw to align the adapter shaft. Secure ball
thrust screws with Loctite
®
243. Remove unused ball thrust screws or secure with
Loctite
®
243. Max. tightening torque for M12 approx. 25 Nm, for M16 approx. 35 Nm.
Use parallel keys to DIN 6885.
Please also observe the supplement data sheet Mounting accuracy for hollow shaft
encoders.
You should also observe the Installation instructions supplied with the adapter shaft
when installing!
1
8
2
3
12
7
6
13
10
15
14
5
4
9
11
Figure.1
: