![Hubner Cobolt 06-01 Series Owner'S Manual Download Page 51](http://html1.mh-extra.com/html/hubner/cobolt-06-01-series/cobolt-06-01-series_owners-manual_2180889051.webp)
51 | 60
OWNERS MANUAL | Cobolt 08-01 Series | D0141-K SEPTEMBER 2020
Clear Fault
-
is displayed in the event of a fault. The user can deal with the cause of the fault and then press “Clear
Fault” and then restart the laser by clicking “Laser ON”. Example: if the remote interlock loop is open the user must
make sure the loop is closed a
gain before issuing a “Clear Fault” followed by “Laser On”.
More
–an additional Cobolt Monitor™ window will open containing more detailed information of that laser’s status.
06-MLD
Cobolt Monitor™ software expanded to for more detailed monitoring.
TEC Settings
–
shows the running status and the fault status for the laser’s internal thermoelectric coolers (TEC).
Laser Operation Mode and Settings
- The user can switch between constant power mode, constant current mode
and modulation mode. Likewise, there are boxes to set the constant power level and constant current level. In
constant power mode the current will be set by Cobolt Monitor to reach the power level set in this field. When in
modulation mode it is recommended to use an external power meter. See section 6 and 7 for more details on
continuous wave and modulation modes.
Autostart Program
- displays whether the laser is in CDRH or OEM mode and displays the current laser operational
status. There are also buttons to “abort” the autostart sequence or to “restart” the laser after a fault.