background image

SECTION 1: INSTALLATION

WARNING

This product may only be installed by a qualified electrical engineer. The unit 

is not designed to be installed upside down or sideways on a wall.

The AM-2 is designed to be wall-mounted or installed flat inside a cabinet. When installing on a 

wall ensure you use Rawl boats to secure the unit to the wall.

DIP SWITCH SETTINGS

Configure each battery address to enable proper setup and communication. Each battery needs 

a unique serial address in order to communicate. If you are only using one battery in your setup, 

ensure you set the battery to Address 1. 

Page 2

DC ISOLATOR

The Hubble AM series of batteries has an integrated electronic circuit breaker built into the BMS. 

The integrated electronic CB is for protecting the battery and the internal cells against overload, 

over current, over volt etc. It is however required to install an external DC fuse or circuit breaker 

before using or operating the batteries. Please ensure you use the correct rating as per battery 

specification.

Summary of Contents for AM-2

Page 1: ...verter and battery setup unless you are certain you understand the risk Speak to a qualified electrician if you are unsure V1 0 Please visit https www hubblelithium co za products html for the latest...

Page 2: ...ON 2 INVERTER SETUP PAGE 5 SECTION 3 LED INDICATORS PAGE 6 SECTION 4 BMS MAINTENANCE PAGE 7 SECTION 5 COMPLETING SETUP PAGE 8 INDEX Information published in this manual is correct as of the date publi...

Page 3: ...AM 2 WIRE DIAGRAM 1 Cover 2 Hanging Ear 3 Handle 4 Output Terminal 6 Cooling Case 7 Power Switch 8 Communication Interface 9 Reset Switch 10 LED Lights Page 1...

Page 4: ...etup and communication Each battery needs a unique serial address in order to communicate If you are only using one battery in your setup ensure you set the battery to Address 1 Page 2 DC ISOLATOR The...

Page 5: ...computer LAN cable to connect each battery The pin layouts for the ports are the same as the universal LAN cable WARNING PROTECTION MODE If your batteries are unbalanced or the voltage of each pack is...

Page 6: ...g devices that are not Hubble Lithium products Third party monitoring and interfacing devices have the potential to change charge voltages and algorithms inadvertently this can cause a catastroph ic f...

Page 7: ...sponding inverter guide https www hubblelithium co za The recommended cutoff is 44V 45V However the internal battery cutoff is as low as 40V Setting the cutoff to 40V will drain the battery to 0 For...

Page 8: ...D as standby Temperature Over current Fault Protection OFF ON OFF OFF OFF OFF DISCHARGE Normal Flash 3 OFF Indication by SOC Alarm Flash 3 Flash 3 Under Discharge Protection OFF OFF OFF OFF OFF OFF Te...

Page 9: ...acity charge discharge current temperature etc This can be downloaded by a service technician to help troubleshoot any issues or problems of the battery MAINTENANCE The Hubble BMS will protect the bat...

Page 10: ...etting up your system please contact our Technical Support Department via support hubblelithium co za Be sure to include the following information in your initial email so that we can provide you with...

Reviews: