IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information and 
instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials, and 
proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and during 
servicing or relamping turn off power at fuse or circuit breaker

All servicing or relamping must be performed by

Part No

…………………

93058705

www

.

s

tru
c

servicing or relamping, turn off power at fuse or circuit breaker.

All servicing or relamping must be performed by 

qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard. 
Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in 
compliance with the National Electrical Code and local codes.

The use of accessory equipment not recommended by 

the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from 
product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or 
the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.

-----------------------------------------------------------------------------------------------------------------------------------------------------------------
WARNING –

Follow the Instructions carefully to assure full compliance with local, state, and NEC requirements. If there are 

any questions, contact a Qualified Electrical Contractor.

prescolite.com

c

tion 

WARNING 

– Risk of fire or electrical shock. Consult a Qualified Electrician to ensure correct branch circuit conductor. 

Install this fixture only in Junction Boxes or Recessed Housings per the dimensions shown. Do not make or alter any holes 
in an enclosure of wiring or electrical components during kit installation. Suitable for use with luminaire with a minimum of
75 C° supply conductors.

WARNING 

– To prevent wiring damage or abrasion, do not expose wiring to edges sheet metal or sharp objects.

NOTE 

– This product is designed to operate with most standard incandescent or low voltage electronic dimmer switches. 

Results may vary. For recommended dimmers, consult product spec sheet or go to www.prescolite.com or call Technical 
Support 1-888-PRS-4TEC.

NOTE 

– SUITABLE FOR WET LOCATIONS IN COVERED CEILINGS

WARNING 

– This product contains chemicals known to the State of California to cause cancer, birth defects and/or other 

Prescolite T

o

ll 

Fre

e

Sh
e

p

,

reproductive harm. Thoroughly wash your hands after installing, handling, cleaning, or otherwise touching this product.

NOTE 

– Always install within ambient temperatures specified on the product specification sheet. 5 year warranty.

See www.prescolite.com for details.

-----------------------------------------------------------------------------------------------------------------------------------------------------------------

e

 T

e

chnical 

Suppo

r

RECESSED

 

HSG

 

DIAMETER

MINIMUM

 

DIAMETER

MAXIMUM

 

DIAMETER

MINIMUM

 

HEIGHT

 

CLEARANCE

4

 

INCH

 

Ø

3

 

7/8"

4

  

1/4"

3

  

1/2"

5

 

INCH

 

Ø

4

 

7/8"

5

 

1/4"

3

  

1/2"

6 INCH Ø

5 7/8"

7 1/8"

3 1/2"

e

et

Install screw into correct mounting hole
for appropriate recessed housing size.

6”         5”         4”

rt  

 

1.888.PRS.4TE

C

6

 

INCH

 

Ø

5

  

7/8

7

  

1/8

3

  

1/2

IMPORTANT!

For recessed housing installation, prior to retrofit installation, the housing must be properly installed and flush 

with the ceiling.  It may be necessary to detach the socket from a mounting bracket inside the housing. Remove and discard the 
bracket to allow adequate clearance. 

1.

Connect Trim to Power

For retrofit:

Screw socket adapter (1) into socket (2) as shown. For junction box mounting always attach the   

C

 

Hours: 8am 

ground wire to the ground screw.

For new construction with dedicated LED housing:

Remove socket adapter assembly (1) and discard. Connect trim  

connector (3) directly to mating housing connector (4) as shown.

2.

Install recessed housing mounting hardware to fixture as shown. Be sure to install spring clips (5) in correct holes 
according to recessed housing diameter.

3.

Insert Trim into Recessed Housing

: Guide socket and wiring toward the housing opening . Push trim up into 

recessed housing while twisting trim 

counterclockwise

1/4 turn, firmly engaging the spring clips (5) until flush with ceiling.

5pm ET

701 Millennium Blvd, Greenville, SC 29607

With representatives office in principal cities throughout North America.
Copyright 2014, 08-06-14 revision, All Rights Reserved

4.

To remove the trim assembly in a housing, twist trim assembly 

counterclockwise

1/4 turn while pulling down.

Reviews: