1. To replace lamp remove eyeball lens frame & gasket with lens.

LAMP / MAINTENANCE INSTRUCTIONS:

Make certain electrical supply is OFF before starting lamp installation.

2. Replace lamp of type and wattage

as shown on fixture label.  NOTE:
After installing lamp let fixture
warm up for 5 minutes before
completely closing.

LIGHTVAULT

®

- LTV Lens Reflector 

LTV55 / 56 & LTV755 / 756

Installation Instructions

!

3. Before closing fixture, clean lens and gasket inside and out.  Be sure gasket

and gasket surface is dry.  Make sure no dirt has fallen into screw holes.
Any foreign object trapped in the gasket will create potential points of
entry for ground water.

MAINTENANCE:

A regularly scheduled maintenance program must be established to keep fixtures clean.  Dried leaves and paper 
can burn if allowed to accumulate on high temperature lenses.  A buildup of dirt and other material on the lens may 
cause excessive temperatures within the fixture.

Clean lens gasket and frame inside and out.  Before closing fixture, be sure gasket and gasket surfaces are clean 
and dry.  Make sure no dirt has fallen into screw holes.

Install lens gasket and lens frame.  Coat screws with silicone grease and tighten progressively and evenly until 
tight.

WARNING:

This H.I.D. / Fluorescent fixture utilizes a lamp that may contain

mercury.  For information on disposal of lamp go to website:

www.lamprecycle.org

Coat screws with silicone
grease and lighten
opposing screws progres
sively and evenly until tight.