Page 3
KIM LIGHTING • 16555 E. Gale Ave. • P.O. Box 60080 • City of Industry, CA 91716-0080 • 626/968-5666 • FAX 626/330-3861
1. To replace lamp remove eyeball lens frame & gasket with lens.
LAMP / MAINTENANCE INSTRUCTIONS:
Make certain electrical supply is OFF before starting lamp installation.
2. Replace lamp of type and wattage
as shown on fixture label. NOTE:
After installing lamp let fixture
warm up for 5 minutes before
completely closing.
LIGHTVAULT
®
- LTV Lens Reflector
LTV55 / 56 & LTV755 / 756
Installation Instructions
!
3. Before closing fixture, clean lens and gasket inside and out. Be sure gasket
and gasket surface is dry. Make sure no dirt has fallen into screw holes.
Any foreign object trapped in the gasket will create potential points of
entry for ground water.
MAINTENANCE:
▼
A regularly scheduled maintenance program must be established to keep fixtures clean. Dried leaves and paper
can burn if allowed to accumulate on high temperature lenses. A buildup of dirt and other material on the lens may
cause excessive temperatures within the fixture.
▼
Clean lens gasket and frame inside and out. Before closing fixture, be sure gasket and gasket surfaces are clean
and dry. Make sure no dirt has fallen into screw holes.
▼
Install lens gasket and lens frame. Coat screws with silicone grease and tighten progressively and evenly until
tight.
WARNING:
This H.I.D. / Fluorescent fixture utilizes a lamp that may contain
mercury. For information on disposal of lamp go to website:
www.lamprecycle.org
Coat screws with silicone
grease and lighten
opposing screws progres
sively and evenly until tight.