Hubbell GAI-TRONICS Clean Phone 295-001F Manual Download Page 1

Pub. 42004-484G 

GAI-TRONICS  3030 KUTZTOWN RD.  READING, PA  19605 USA 

610-777-1374  

  800-492-1212  

  Fax:  610-796-5954 

V

ISIT WWW

.

GAI

-

TRONICS

.

COM FOR PRODUCT LITERATURE AND MANUALS

 

 

ATTENTION! 

Replacing  an  existing  Model  295F  or 
295W with this telephone (Model 295-
001F or 295-001W) requires removing 
the existing 48 V dc power supply and 
replacing  it  with  the  5  V  dc  power 
supply  included  with  this  telephone 
(or other 5 V dc source). 
Connecting 48 V dc to this telephone 
will cause severe damage. 

 

Summary of Contents for GAI-TRONICS Clean Phone 295-001F

Page 1: ...RODUCT LITERATURE AND MANUALS ATTENTION Replacing an existing Model 295F or 295W with this telephone Model 295 001F or 295 001W requires removing the existing 48 V dc power supply and replacing it wit...

Page 2: ...to Answer 2 Models 3 TMA Telephone Management Application 3 Operation 4 Placing an Autodial Call 4 Placing a General Telephone Call 4 Receiving a Call 4 Installation 4 General Information 4 Safety Gui...

Page 3: ...rogramming Sequences 16 Dialing Methods 16 Password Protection 18 Auto Answer Alert Feature 19 Off Hook Ringing 19 Disconnect Options 20 Output One Extended Control Operation 20 Output Four Control Se...

Page 4: ...only be used in connection with the operation of your GAI Tronics product or system This manual may not be disclosed in any form in whole or in part directly or indirectly to any third party Product O...

Page 5: ...It is important to program the Auto dial Time Delay option if using the auto dial feature This sets the amount of time lapse between the auto dial button press and the actual dialing operation The 10...

Page 6: ...he basic TMA package Model 12509 042 includes a single line transceiver for polling a single telephone at a time Each telephone requires approximately 90 seconds to relay its health status to TMA Use...

Page 7: ...all timeout Receiving a Call The Clean Phone analog telephone automatically goes off hook auto answers when the unit is called This is the default operating mode The Clean Phone analog telephone can b...

Page 8: ...strikes The lightning arrestor must be installed as close to the telephone as possible to maximize the protection It must not be installed within the enclosure supplied with the phone Do not install...

Page 9: ...oles in the lower right and upper left corners and secure the bracket with screws 7 Drill the remaining holes and secure the bracket with the remaining screws 8 Connect the field telephone line to the...

Page 10: ...Pub 42004 484G Clean Phone Analog Telephones Page 7 of 26 P Standard IOMs Current Release 42004 Instr Manuals 42004 484G docx 04 19 Figure 4 Inside Front Panel...

Page 11: ...484G Clean Phone Analog Telephones Page 8 of 26 P Standard IOMs Current Release 42004 Instr Manuals 42004 484G docx 04 19 Figure 5 Wall Cut out Dimensions for Model 295 001F Figure 6 Back Box for Mode...

Page 12: ...end of the cable 5 Snap the bushing closed and insert it into the double D hole in the back of the back box see Figure 3 and Figure 8 6 Secure the back box to the mounting surface 7 Connect the field...

Page 13: ...and Figure 9 for the location of P18 The No 40411 005 power supply has a 4 foot cord for connecting the Clean Phone analog telephone Splice additional wire to the existing power supply cord to obtain...

Page 14: ...the power supply into an electrical outlet until the installation is complete Each Clean Phone analog telephone requires its own dedicated 5 V dc power source for proper operation Configuration The h...

Page 15: ...as polarity or non polarity sensitive The telephone operates regardless of tip and ring polarity when configured for non polarity The telephone will only operate when the telephone line s positive ter...

Page 16: ...ach telephone includes two isolated solid state switches capable of switching a maximum of 125 mA at 48 V dc or 80 mA at 28 V ac TB2 OUT1 and TB5 OUT4 on the emergency telephone PCBA provide the conne...

Page 17: ...configured for monitoring Normal telephone operation is identical in both modes of operation Each Clean Phone analog telephone is factory programmed to receive standard mode commands see Table 12 for...

Page 18: ...nect to the telephone authenticate and enter a programming sequence is shown below see Figure 10 3 Continue programming the telephone see the Programming Sequences section RemoteAccessProgramming 1 En...

Page 19: ...utomatically end the programming call within 20 seconds NOTES The Clean Phone analog telephone automatically times out and disconnects after 20 seconds elapses between digit entries or if an invalid p...

Page 20: ...er NOTE The secondary dial tone delay can only be used if a 9 must be entered to gain access to the CO line The AUTO DIAL2 push button can only be programmed for a single telephone number when operati...

Page 21: ...n to the appropriate telephone after the button is pressed None Ring down Operation Ring down operation enables the telephone to go off hook when the AUTO DIAL1 push button is pressed Ring down operat...

Page 22: ...alert tone L 0 Enable alert tone L 1 1 Enabled Off HookRinging The telephone can generate a ringing signal from the speaker when the telephone is called The factory default setting for this feature is...

Page 23: ...es Dial Tone Disconnect Option 1 9 L NOTE Use this option only if no other disconnect options are available The telephone automatically terminates a call if it detects a dial tone continuously for 10...

Page 24: ...second to 12 7 seconds in 0 1 second increments Use 000 to disable this feature To set a duration of 7 seconds enter 2 6 0 7 0 5 seconds EarlyMicrophoneOption The microphone in each telephone activate...

Page 25: ...ion of microphone Yes SMART Mode Programming The TMA software is designed to remotely program Clean Phone analog telephones for SMART mode operation The telephones can be locally programmed for SMART...

Page 26: ...Dial Tone Delay 11NN 2 seconds Ring down Operation 1 None Password Protection Feature Programming see Table 5 Password Protection 14NNNN 2468 Disconnect Options Programming see Table 8 Call Time out...

Page 27: ...ip equipment prepaid to GAI Tronics with a return authorization number and a purchase order number Repairs will be made without charge if the equipment is under warranty Please include a written expla...

Page 28: ...ted Chemical Resistance The Clean Phone analog telephone graphic overlay is designed to withstand exposure to many chemicals Please contact the factory for questions pertaining to chemicals not listed...

Page 29: ...5 001W Clean Phone Analog Telephone Construction Front panel 8 mil polyester over 16 gauge stainless steel Back enclosure 16 gauge stainless steel Dimensions Front panel 12 00 W 12 00 H in 304 8 304 8...

Page 30: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Reviews: