Pub. 42004-561A
400-005 and 400-006 RigCom Stations
Page 14 of 16
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-561A.docx
04/22
Mechanical
Construction/finish ......................................................................................... cast aluminum/tumblfast finish
Mounting .................................................................wall or column, four 7/16-inch mounting feet with slots
Connections....................................................................................................... plug-in style terminal blocks
Conduit entries
bottom: ................................................................................................................. two, 3/4-inch NPT
top: ................................................................................... one, 1/2-inch NPT (Model 400-006 only)
Dimensions ..................................................... 20.5 H × 10.25 W × 14.21 D in (520.9 × 260.2 × 360.9 mm)
Shipping weight
Model 400-005 ........................................................................................................ 40.0 lb (18.1 kg)
Model 400-006 ........................................................................................................ 27.0 lb (12.2 kg)
Environmental
Temperature range (operating and storage) ........................................... –4 ºF to +140 ºF (–20 ºC to +60 ºC)
Approvals
The models below are approved for the following hazardous areas when installed in accordance with Pub.
42004-562, RigCom UL Control Drawing No. 75614.
Model 400-005 RigCom Station:
NRTL listed (USA) ....................................................... Hazardous locations Class I, Div. 1, Groups C & D
When using auxiliary microphone and/or footswitch: ............ Hazardous locations Class I, Div. 1, Group D
Model 400-006 RigCom Station:
NRTL listed (USA) ................................................... Hazardous locations Class I, Div. 1, Groups B, C & D
When using auxiliary microphone and/or footswitch: ............ Hazardous locations Class I, Div. 1, Group D
Appendix A—
Interfacing a Model
400-005
RigCom Station to EZ
Page Stations
The Model 400-005 RigCom Station operates as an addition to a system of EZ Page stations.
The EZ Page Series and Model 400-005 Stations operate in either balanced or unbalanced systems. An
unbalanced communication system uses the negative of the audio pair as the ground reference for the
control signal. The audio pair is not ground referenced in a balanced system and the control signal
requires a separate ground signal.
Configure the Model 400-005 RigCom stations and the EZ Page stations identically as balanced or
unbalanced using jumper
P3
on the Model 400-005 station(s) and jumper
P5
on the EZ Page station(s)
for interoperability between the Model 400-005 RigCom and the EZ Page Series stations.