Hubbell GAI-TRONICS 234 Manual Download Page 7

Pub.  42004-194H

Model 234 Stanchion Assembly

Page:  

7 of 11

d:\standard ioms - current release\42004 instr. manuals\42004-194h.doc

09/05

Model 84503 Stanchion Panel Light Installation

1.

 

Remove the two screws securing the bezel and lens to the
stanchion panel light assembly.

2.

 

Align the stanchion panel light assembly inside the
stanchion as shown in Figure 7.

3.

 

Extend the black (hot) and the white (neutral) wires to the
base of the stanchion (these wires will be connected later,
along with the beacon wires, to the incoming power wires
in accordance with the electrical codes).

4.

 

Secure the light assembly with the two mounting screws
provided.  Apply a small amount of clear RTV silicone
sealant or equivalent to each screw thread to reduce the
possibility of rust forming in the screw threads.

5.

 

Insert the 7-watt compact fluorescent bulb provided with
the assembly.

6.

 

Secure the bezel and the lens to the stanchion.

Figure 7.  Stanchion Panel

Light Assembly

Summary of Contents for GAI-TRONICS 234

Page 1: ...uals to assist in properly installing a complete station Pub No Emergency Phone Model Pub 42004 284 Model 530FB Strobe with Dual Constant On Lamps Pub 42004 352 Model 297 001 Flush Mount Emergency Pho...

Page 2: ...AI Tronics The following materials are necessary to construct the reinforcement cage four 4 rebars three 4 ties one 18 inch sonotube 1 Construct the reinforcement cage by placing a horizontal member i...

Page 3: ...Grounding electrode conductor not depicted in the illustration must be constructed in accordance with the National Electrical Code and applicable local codes Model 84504 Hardware Kit Installation The...

Page 4: ...chion Assembly Page 4 of 11 d standard ioms current release 42004 instr manuals 42004 194h doc 09 05 NOTE The stanchion should not be mounted until the concrete has been allowed to cure for a minimum...

Page 5: ...hex nut See Figure 5 and Figure 6 3 Before mounting the stanchion unscrew the four tamper resistant screws on the rear handhole cover and remove the cover 4 Apply a small amount of clear RTV silicone...

Page 6: ...st exist between the base of the stanchion and the top of the concrete pier See Figure 6 This air gap must not be obstructed with soil mulch stone etc The unit should be installed and grounded in acco...

Page 7: ...hot and the white neutral wires to the base of the stanchion these wires will be connected later along with the beacon wires to the incoming power wires in accordance with the electrical codes 4 Secu...

Page 8: ...res to extend to the base of the stanchion See Figure 8 2 Screw the beacon onto the threaded nipple Secure the lens cover Model 84502 with four tamper resistant screws 3 Apply a small amount of clear...

Page 9: ...ly on the protection bracket on the bottom of the stanchion wall mounting assembly 4 Install a ground wire between the telephone line surge suppressor sold separately and the grounding lug on the bott...

Page 10: ...accordance with the National Electrical Code NEC in the United States or the Canadian Electrical Codes CEC in Canada Install the power lines as follows 1 Install the recommended ac power line surge s...

Page 11: ...e to loosen and lift a corner edge of the damaged decal 2 Carefully peel back and remove the loosened decal 3 Wipe the area clean with denatured alcohol Allow the area to dry 4 Prior to attaching a ne...

Page 12: ...be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services exceed 100 of the total cost of services provided hereunder Warranty Periods Every...

Reviews: