Pub. 42004-194H
Model 234 Stanchion Assembly
Page:
7 of 11
d:\standard ioms - current release\42004 instr. manuals\42004-194h.doc
09/05
Model 84503 Stanchion Panel Light Installation
1.
Remove the two screws securing the bezel and lens to the
stanchion panel light assembly.
2.
Align the stanchion panel light assembly inside the
stanchion as shown in Figure 7.
3.
Extend the black (hot) and the white (neutral) wires to the
base of the stanchion (these wires will be connected later,
along with the beacon wires, to the incoming power wires
in accordance with the electrical codes).
4.
Secure the light assembly with the two mounting screws
provided. Apply a small amount of clear RTV silicone
sealant or equivalent to each screw thread to reduce the
possibility of rust forming in the screw threads.
5.
Insert the 7-watt compact fluorescent bulb provided with
the assembly.
6.
Secure the bezel and the lens to the stanchion.
Figure 7. Stanchion Panel
Light Assembly