Hubbell GAI-TRONICS 234 Manual Download Page 10

Pub.  42004-194H

Model 234 Stanchion Assembly

Page:  

10 of 11

d:\standard ioms - current release\42004 instr. manuals\42004-194h.doc

09/05

9.

 

Attach the telephone cable from the surge suppressor to TB1 on the telephone PCBA as shown in
Figure 9.

10.

 

Attach the strobe’s violet and orange control wires to TB2 on the telephone PCBA as shown in Figure
9.

Install the phone’s front panel using the six tamper-resistant screws and six washers provided.

N

OTE

:

   Excessive tightening will cause the panel to warp.  Do not over-tighten.

Wiring Power Connections

All wiring connections should be complete at this point, with the exception of the stanchion panel light
and beacon wire connections to the incoming power lines.  All connections must be made in accordance
with the National Electrical Code (NEC) in the United States or the Canadian Electrical Codes (CEC) in
Canada.  Install the power lines as follows:

1.

 

Install the recommended ac power line surge suppressor on the protection bracket.

2.

 

Install a ground wire between the telephone line surge protection and the grounding lug.

3.

 

Connect the incoming ac power line to the surge protection as shown in Figure 9.

4.

 

Connect the red, white, and green wires of the Model 530FB AC Beacon to the surge protection as
shown in Figure 9.  When using the Model 531A DC Beacon, connect the red and white wires to the
dc power source as shown in Figure 10.

5.

 

Connect the black, white, and green wires of the telephone light to the surge protection.

Figure 10.  Interconnection diagram with dc beacon

After making these connections according to the prevailing electrical codes, replace the handhole cover at
the stanchion base using tamper-resistant screws.

Summary of Contents for GAI-TRONICS 234

Page 1: ...uals to assist in properly installing a complete station Pub No Emergency Phone Model Pub 42004 284 Model 530FB Strobe with Dual Constant On Lamps Pub 42004 352 Model 297 001 Flush Mount Emergency Pho...

Page 2: ...AI Tronics The following materials are necessary to construct the reinforcement cage four 4 rebars three 4 ties one 18 inch sonotube 1 Construct the reinforcement cage by placing a horizontal member i...

Page 3: ...Grounding electrode conductor not depicted in the illustration must be constructed in accordance with the National Electrical Code and applicable local codes Model 84504 Hardware Kit Installation The...

Page 4: ...chion Assembly Page 4 of 11 d standard ioms current release 42004 instr manuals 42004 194h doc 09 05 NOTE The stanchion should not be mounted until the concrete has been allowed to cure for a minimum...

Page 5: ...hex nut See Figure 5 and Figure 6 3 Before mounting the stanchion unscrew the four tamper resistant screws on the rear handhole cover and remove the cover 4 Apply a small amount of clear RTV silicone...

Page 6: ...st exist between the base of the stanchion and the top of the concrete pier See Figure 6 This air gap must not be obstructed with soil mulch stone etc The unit should be installed and grounded in acco...

Page 7: ...hot and the white neutral wires to the base of the stanchion these wires will be connected later along with the beacon wires to the incoming power wires in accordance with the electrical codes 4 Secu...

Page 8: ...res to extend to the base of the stanchion See Figure 8 2 Screw the beacon onto the threaded nipple Secure the lens cover Model 84502 with four tamper resistant screws 3 Apply a small amount of clear...

Page 9: ...ly on the protection bracket on the bottom of the stanchion wall mounting assembly 4 Install a ground wire between the telephone line surge suppressor sold separately and the grounding lug on the bott...

Page 10: ...accordance with the National Electrical Code NEC in the United States or the Canadian Electrical Codes CEC in Canada Install the power lines as follows 1 Install the recommended ac power line surge s...

Page 11: ...e to loosen and lift a corner edge of the damaged decal 2 Carefully peel back and remove the loosened decal 3 Wipe the area clean with denatured alcohol Allow the area to dry 4 Prior to attaching a ne...

Page 12: ...be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services exceed 100 of the total cost of services provided hereunder Warranty Periods Every...

Reviews: