Hubbell GAI-TRONICS 234 Manual Download Page 1

Pub.  42004-194H

GAI-Tronics Corporation  P.O. Box 1060, Reading, PA  19607-1060  USA

610-777-1374  

„

  800-492-1212  

„

  Fax:  610-796-5954

V

ISIT WWW

.

GAI

-

TRONICS

.

COM FOR PRODUCT LITERATURE AND MANUALS

G A I - T R O N I C S ®   C O R P O R A T I O N

A   H U B B E L L   C O M P A N Y

Model 234 Stanchion Assembly

Confidentiality Notice

This manual is provided solely as an installation, operation, and maintenance guide and contains sensitive
business and technical information that is confidential and proprietary to GAI-Tronics.  GAI-Tronics
retains all intellectual property and other rights in or to the information contained herein, and such
information may only be used in connection with the operation of your GAI-Tronics product or system.
This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party.

Introduction

The complete emergency station is shipped in two stages.  The Model 84504 Hardware Kit is usually
shipped in advance followed by the remaining assemblies (Model 84501, Model 84502, and Model
84503).  In addition to this publication, refer to the following manuals to assist in properly installing a
complete station:

Pub. No.

Emergency Phone Model

Pub. 42004-284

Model 530FB Strobe with Dual Constant-On Lamps

Pub. 42004-352

Model 297-001 Flush-Mount Emergency Phone

Pub. 42004-351

Model 297-003 S.M.A.R.T. Flush-Mount Emergency Phone

Pub. 42004-352

Model 298-001 Flush-Mount Emergency Phone with Keypad

Pub. 42004-351

Model 298-003 S.M.A.R.T. Flush-Mount Emergency Phone with Keypad

The Model 234 Stanchion Assembly is designed to house a Model 298 or 297 Emergency Telephone and
a Model 530FB or 531A Beacon.  This aesthetically-pleasing stanchion is over 9 feet tall, making it easily
located by potential users.

The beacon creates added noticeability to emergency telephone locations by providing a constant-on lamp
and a flashing strobe light is automatically engaged when the emergency button is pressed.  The telephone
is also highly visible; a light mounted in the stanchion shines on the front panel of the telephone to
illuminate the phone for nighttime use.

GAI-Tronics enhanced emergency telephones are designed for isolated high-risk areas requiring
emergency communications equipment.

Emergency telephone users simply press the clearly labeled emergency push button for immediate
connection to a user-programmed central security telephone number.

Summary of Contents for GAI-TRONICS 234

Page 1: ...uals to assist in properly installing a complete station Pub No Emergency Phone Model Pub 42004 284 Model 530FB Strobe with Dual Constant On Lamps Pub 42004 352 Model 297 001 Flush Mount Emergency Pho...

Page 2: ...AI Tronics The following materials are necessary to construct the reinforcement cage four 4 rebars three 4 ties one 18 inch sonotube 1 Construct the reinforcement cage by placing a horizontal member i...

Page 3: ...Grounding electrode conductor not depicted in the illustration must be constructed in accordance with the National Electrical Code and applicable local codes Model 84504 Hardware Kit Installation The...

Page 4: ...chion Assembly Page 4 of 11 d standard ioms current release 42004 instr manuals 42004 194h doc 09 05 NOTE The stanchion should not be mounted until the concrete has been allowed to cure for a minimum...

Page 5: ...hex nut See Figure 5 and Figure 6 3 Before mounting the stanchion unscrew the four tamper resistant screws on the rear handhole cover and remove the cover 4 Apply a small amount of clear RTV silicone...

Page 6: ...st exist between the base of the stanchion and the top of the concrete pier See Figure 6 This air gap must not be obstructed with soil mulch stone etc The unit should be installed and grounded in acco...

Page 7: ...hot and the white neutral wires to the base of the stanchion these wires will be connected later along with the beacon wires to the incoming power wires in accordance with the electrical codes 4 Secu...

Page 8: ...res to extend to the base of the stanchion See Figure 8 2 Screw the beacon onto the threaded nipple Secure the lens cover Model 84502 with four tamper resistant screws 3 Apply a small amount of clear...

Page 9: ...ly on the protection bracket on the bottom of the stanchion wall mounting assembly 4 Install a ground wire between the telephone line surge suppressor sold separately and the grounding lug on the bott...

Page 10: ...accordance with the National Electrical Code NEC in the United States or the Canadian Electrical Codes CEC in Canada Install the power lines as follows 1 Install the recommended ac power line surge s...

Page 11: ...e to loosen and lift a corner edge of the damaged decal 2 Carefully peel back and remove the loosened decal 3 Wipe the area clean with denatured alcohol Allow the area to dry 4 Prior to attaching a ne...

Page 12: ...be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services exceed 100 of the total cost of services provided hereunder Warranty Periods Every...