WATER HEATER PROGRAMMING SECTION
Press the
Up/Down
arrows to set the
desired temperature.
When the Commercial mode is OFF, the maximum
temperature setting is 140°F. When the Commercial
mode is on the maximum temperature, setting is 185°F.
Press and hold the control panel
Power
button
to turn the water heater OFF.
Press control panel
Power
button to turn the
water heater back ON.
Watch the display for “
CH
”, which appears momentarily
before the display shows the actual temperature.
NOTE:
When changing the mode back to
residential hot water (
dH
), the temperature setting
will remain above the maximum limit until the
down arrow is pressed.
Leak Action Selection
If turned ON and a leak is detected, water will
automatically be shut off. If turned OFF, the
leak will continue. High condensation within the
tank can sometimes produce a false reading. This mode
is turned OFF by default.
The Leak Action mode is an ON or OFF selection.
Set
Press and hold the
Set
button.
Then use the
Up/Down
arrows to select the
programming mode
LA
on the display.
Enter
Press the
Enter
button to begin programming.
P ress the
Up/Down
arrows to select either
ON or OFF.
Mode
Press and hold the
Mode
button to save the
changes and return to the
dH
screen on the
main display.
Enter
Press the
Enter
button to return to the main
display.