Due to its efficient design, the
Hubbell
water heater
produces condensate (water) as a normal by-product of
heating the water. This condensate is acidic, with a pH
level between 3 and 4. Local building codes may require
an in-line neutralizer to be installed (not included) to treat
this water.
1. Connect 3/4” I.D. fl exible drain line (2) to the
condensate nipple located on the bottom of the unit.
Tighten hose clamp (1).
2. If required, install an in-line neutralizer (3) to treat
the acidic condensate. Follow all the installation
instructions included with the neutralizer.
NOTE:
If a nearby laundry tub is used as a
disposal for waste water from a washing machine,
draining the condensate into this tub allows the
soapy water discharge to neutralize the acidic
condensate.
3. Route the drain line to nearby laundry tub (6), fl oor
drain (5), or condensate pump (4).
INSTALL CONDENSATE DRAIN
IH-30
1
2
5
3
6
4