Installation
1. Do not install the NX energyHUBB in an unconditioned space.
2. The NX energyHUBB is shipped completely assembled but requires further installation and connections.
3. Identify a suitable location to mount the enclosure assembly. Ideally, it should be mounted right next to the NX Area
Controller.
4. Wall mount the enclosure assembly using appropriate mounting screws (not included) according to the 4 mounting
keyholes (See Figure 1). Note: An optional mounting foot with screws is provided for ease of wall mounting.
5. Open the enclosure door and identify the power cables (red and black wires.) Before proceeding further, flip open
the circuit breaker mounted inside the enclosure. Now proceed with connection to a power source of 120V.
Carefully follow the wire color markings on the power supply housing.
6. All additional connections to the NX energyHUBB will be made using CAT5e cable with RJ-45 connectors.
7. The NX energyHUBB module housed inside the enclosure comes with a 10/100 Base-T Ethernet connection via the
RJ-45 Port. The RJ-45 port has two LEDs. When the device is connected to the network the blue LEDs are lit, and flash
when there is network activity.
8. Connect one end of your CAT5e Ethernet cable to the RJ-45 port and the other end to the Ethernet port on the NX
Area Controller. See Figure 3 & 4.
9. Use the second Ethernet port on the NX energyHUBB module to connect your PC. See Figure 3 & 4.
As an alternative option, if the user wants to connect the NX energyHUBB to their building LAN network, use the
second RJ-45 port on the module to connect the building router instead of the PC. Refer to the diagram in Figure 2.
10. Route the Ethernet and power cables through the provided knock-outs as shown in Figure 3.
11. Make sure to close the enclosure door once all connections and installation is complete.
To NX Area Controller and PC/LAN
Primary RJ-45 Port
Connect NX Area Controller Here
Secondary RJ-45 Port
Connect your PC Here
To Main Power (120V 60Hz)
Figure 3: Key Access Points