Page
9 of 26
Model 298 ADA-Compliant Emergency Telephone
Pub. 42004-304A
f:\standard ioms - current release\42004 instr. manuals\42004-304a.doc
06/02
4.
Dial the four-digit password. If the password has not been altered, dial
2468
(factory setting).
Otherwise, dial the preprogrammed user password. A success tone (single beep) is generated to
indicate the programming mode has been accessed.
Notes:
•
The telephone will automatically time-out if 20 seconds elapse between digit entries, or if an
invalid password is entered.
•
If DTMF digits have not been dialed within 7 seconds of the call initiation, the telephone remains
off-hook and the programming mode is terminated.
•
If the success tone is not generated, the telephone has failed to recognize the password. Therefore,
the telephone must then be programmed with the password disabled. See the Password Disabled
Programming section on page 9.
5.
If the success tone has been generated, begin entering the desired user-programmable parameters. See
the Programming Sequences section on page 10. A success tone (single beep) is generated each time a
new parameter is accepted. An error tone (two beeps) is generated to indicate an error. If an error tone
is generated, verify the programming sequence, and enter the sequence again.
6.
Terminate the programming by placing the touch-tone telephone on-hook.
Password Disabled Programming
1.
Disable the password protection feature—insert the
J9
jumper on pins 2 and 3.
2.
Enable the auto-answer feature—insert the
J2
jumper on pins 1 and 2.
3.
Using the touch-tone telephone, call the emergency telephone. The emergency telephone will
automatically answer the call and generate a splash tone followed by a success tone (single beep).
4.
Begin entering the desired programmable parameters. See the Programming Sequences section on
page 10. A success tone (single beep) is generated each time a new parameter is accepted. An error
tone (two beeps) is generated to indicate an error. If an error tone is generated, verify the programming
sequence, and enter the sequence again.
Note
: The telephone will automatically time-out if 20 seconds elapse between digit entries.
5.
Terminate the programming by placing the touch-tone telephone on-hook.
LOCAL PROGRAMMING
1.
Connect the Model H94052 Programmer (purchased separately) to connector
J3
. See Figure 3 for
details.
2.
Temporarily move the
E
MERGENCY
push-button switch harness from connector
J8
to the
CALL
push-button connector
J1
.
3.
Disable the password protection feature—insert the
J9
jumper on pins 2 and 3.
4.
Press the
E
MERGENCY
push button. A dial tone will be broadcast over the speaker. Simultaneously
press
1
and
#
on the Model H94052 Programmer. The telephone will generate a success tone
(high-low-high tone).