background image

1

I.Important Note

If the instrument is not in use, please turn off the power in time.

If the instrument is not used for a long time, please charge and discharge regularly.

Batteries should be charged and discharged at least once a month.

It is strictly forbidden to use power shortage, which will severely shorten the battery

life and even make the battery scrap. When the instrument is short of power, the power

supply should be switched off and charged immediately. Avoid battery failure due to

excessive battery discharge time.

Charging lamp: the charging lamp on the charger is bright red during charging and

bright green after charging.

Users must not disassemble the instrument and replace the battery without

authorization. When the instrument or battery fails, please return to the factory.

II.Introduction

Hand-held transformer turn ratio tester is an innovative product with compact size,

hand-held operation, more portable and easy to carry.

Products are mainly applied to change than group test transformer, PT and CT

polarity test, test speed, high accuracy.

III.Packaging Content

After receiving the packing box, open the packing box and check if there is any

damage. If the freight packing box is damaged or the liner material is indented, please

inform the freight company or our salesman immediately.

Please check if you have received the following items in the product package

Standard accessories

√1 Hand-held transformer turn ratio tester

√1 sets of test lines (red and black each)

√1 charger

√1 external printer (with printing cable attached

√1 wrist band (attached to a hand-held tester)

Summary of Contents for HZBB-10S

Page 1: ...HZBB 10S Portable Transformer Turns Ratio Tester Huazheng Electric Manufacturing Baoding Co Ltd...

Page 2: ...manual and operate and maintain the instrument according to the manual to prolong its service life Just a light press the test will be completed automatically is the operating characteristics of this...

Page 3: ...aging Content 1 IV Functional Characteristics 2 V Technical Indicators 2 VI Adjust The Wristband 3 VII Battery Charging 3 VIII Tilt Hand held Tester 4 IX Product Appearance 4 X Operation Instructions...

Page 4: ...e battery without authorization When the instrument or battery fails please return to the factory II Introduction Hand held transformer turn ratio tester is an innovative product with compact size han...

Page 5: ...e polarity test function of CT variable ratio is added and the application field is wider Wide range and high accuracy the variable ratio measurement range can reach 10 000 and the test accuracy can b...

Page 6: ...ure 10 50 Relative humidity 90 No dew VI Adjust The Wristband For better grip strip the belt and adjust the adhesive tape as shown in the following figure VII Battery Charging When the battery is low...

Page 7: ...ld Tester In order to take the instrument or expose the side interface during operation the hand held tester can be tilted as shown in the figure below Lift the tilt seat and pull outward IX Product A...

Page 8: ...yellow and green test lines are connected to single phase test Low voltage test terminal The yellow green and red three color junction bases correspond to the three phase of a B and C respectively an...

Page 9: ...ted to the high voltage end of the tested product and the yellow and green test clamps of the black test line at the low voltage test end are connected to the low voltage end of the tested product Sin...

Page 10: ...of printer paper tear the teeth out a little bit Close the cover and press the print head to the print head Press the print head back to the print head with a bit of force Operation instruction After...

Page 11: ...e of the instrument Need a password operation it is not open to the user 5 SV Display software current version number HV Display hardware current version number The function and operation of are descr...

Page 12: ...e connection mode and connection group of the tested products Group When the user chooses the known connection mode the measurement and display of the instrument are based on the user s input When the...

Page 13: ...strument detects short circuit high and low voltage reverse connection fault the display screen will pop up the fault alarm box and stop measuring The three phase ratio test results screen is shown be...

Page 14: ...ing according to the high side pressure regulating design is to assume that one point as the highest voltage range if the voltage reverse design or tap changer in low voltage side of transformer displ...

Page 15: ...12 XII Packing List No Item Qty 1 Main engine 1 2 Red test line 1 3 Black test line 1 4 Print paper 2 5 Power line 1...