I.Overview

This instrument is used to measure the calorific value of solid, liquid and other

combustible materials (coal, petroleum food, wood, biomass).

The instrument is a new type of energy-saving analysis instrument developed by our

company. The calculation program carefully compiled improves the measurement

accuracy greatly. Color and touch display

,

good user interface. The measurement process

is automatically controlled to reduce human error. Print cartridge, dry base high position

The results are clear and clear.

II.Technical features

1. It has the advantages of simple structure, reliable performance and strong

anti-interference ability.

2. The test steps such as flushing, discharging, water level setting, mixing, ignition,

temperature recovery, correction, calculation and printing are completed automatically to

avoid human error and improve the accuracy and precision.

3.

3The unique calibration technology makes the requirements of the instrument to the

environment relatively relaxed. The accuracy of the test is improved while the stability of

the long-term operation is ensured.

III.Working principle

0.9-1.1g of the substance to be tested is put into a heat crucible (heat-resistant and

anti-corrosion), and the crucible is placed in an oxygen bomb added with 2.8-3.2mpa

oxygen, and put into the inner cylinder of the calorimeter. The inner cylinder is added with

quantitative distilled water. The heat output of the combustible can be calculated

according to the rise of water temperature and the heat capacity of the calorimetry

system.

IV.Technical index

Heat capacity: About 10500 J / K

Oxygen bomb capacity: 300ml

Oxygen charging pressure: 2.8 ~ 3.2 MPa

Summary of Contents for HZ-384A

Page 1: ...HZ 384A Automatic Calorific Value Tester Huazheng Electric Manufacturing Baoding Co Ltd...

Page 2: ...al and operate and maintain the instrument according to the manual to prolong its service life Just a light press the test will be completed automatically is the operating characteristics of this inst...

Page 3: ...nts I Overview 1 II Technical features 1 III Working principle 1 IV Technical index 1 V Instrument structure and auxiliary equipment 2 VI How to use the instrument 2 VII Common faults and troubleshoot...

Page 4: ...emperature recovery correction calculation and printing are completed automatically to avoid human error and improve the accuracy and precision 3 3The unique calibration technology makes the requireme...

Page 5: ...ser interface and so on 2 The water tank is made of stainless steel and plastic VI How to use the instrument 1 Preparation before use Open box inspection after unpacking check whether the appearance o...

Page 6: ...strument 2 Instructions for use of the instrument The main interface of the instrument is as follows Figure 1 1 system system click system setting to enter the system setting menu as shown in the figu...

Page 7: ...of the instrument is directly input according to the data on the package of the reference material used Click return to save and return to the main interface of the system water injection time click...

Page 8: ...matic printing that is the test results will be printed automatically after the test 1 It means manual printing The result will not be printed after the test but can be printed by clicking Print manua...

Page 9: ...on the ignition circuit To detect the ignition circuit Click the mixing test and the MCU sends out the mixing command to switch on the mixing It is used to detect the stirring circuit Click water inj...

Page 10: ...o the following Click calorific value input as follows Input the weight of the sample if no additives are used you can input 0 serial number hydrogen sulfide water and other experimental data and clic...

Page 11: ...e processing trace so as not to affect the print results 5 reset Press this key and the instrument will return to the power on state 6 Thermal capacity calibration Weigh benzoic acid 0 9 1 1g load oxy...

Page 12: ...cible it is easy to burn the crucible and electrode at this time Check whether the wiring is well connected whether the oxygen warhead is in good contact with the ignition cap and whether the oxygen b...

Page 13: ...ng instrument 1 5 Pressure gauge 1 6 Ignition wire 3 7 Cotton 1 8 Benzoic acid 1 9 Add drain pipe 1 10 Tweezers 1 11 Printing paper 2 12 Oxygen bomb support 1 13 crucible 5 14 Oxygen bomb sealing ring...

Reviews: