background image

1

I.Scope of application

For industrial enterprises, universities and colleges, scientific research and related

laboratory for items, drying, baking, wax melting and sterilization.

II.Technical indicators

Model

9030A

9070A

9140A

9240A

9420A

9620A

The

power

supply

voltage

AC220V 50Hz

AC380V 50Hz

Range of temperature

RT+10

℃~

200

Temperature resolution

0.1

Temperature uniformity

±2.5

%

Temperature fluctuation

degree

±1.0

Rated power

700W

1000W

1600W

2000W

2600W

3600W

The tank size (cm)

30×30×35

40×40×4

5

45×55×

55

50×60×7

5

60×55×13

0

80×60×13

0

Overall dimensions(cm)

45×47×70

55×60×8

0

64×73×

90

88×72×9

3

78×71×17

8

98×80×17

8

Shelf

2pcs

2pcs

2pcs

2pcs

3pcs

3pcs

Model

9036A

9076A

9146A

9246A

9426A

9626A

The

power

supply

voltage

AC220V 50Hz

AC380V 50Hz

Range of temperature

RT+10

℃~

300

Temperature resolution

0.1

Temperature uniformity

±2.5

%

Temperature fluctuation

degree

±1.0

Rated power

950W

1400W

2000W

2600W

3500W

3700W

Summary of Contents for 9030A

Page 1: ...DHG Series Electrothermal Blast Drying Oven with Intelligent Timing Huazheng Electric Manufacturing Baoding Co Ltd...

Page 2: ...read this manual and operate and maintain the instrument according to the manual to prolong its service life Just a light press the test will be completed automatically is the operating characteristic...

Page 3: ...ntents I Scope of application 1 II Technical indicators 1 III Summary of structure 2 IV Method of use 2 V 1 Panel Instructions 3 VI Matters needing attention 9 VII Fault handling 9 VIII Packing list 1...

Page 4: ...ture uniformity 2 5 Temperature fluctuation degree 1 0 Rated power 700W 1000W 1600W 2000W 2600W 3600W The tank size cm 30 30 35 40 40 4 5 45 55 55 50 60 7 5 60 55 13 0 80 60 13 0 Overall dimensions cm...

Page 5: ...terial heated in the cabinet can be observed clearly Studio and joint with heat resistant silicon rubber sealing ring the door is in place to ensure that the studio and the seal between the door Dryin...

Page 6: ...etting mode this symbol appears 2 SET Only in setting mode this symbol appears 3 RUN This symbol always appear unless the timing program is over 4 STOP This symbol appears to show you timing program i...

Page 7: ...ll be saved automatically With timing function Press the SET button in the non set state windows display the prompt SP and temperature set value Re press the SET button windows display the prompt ST a...

Page 8: ...am In the auto tuning process the SET button is invalid the under window always displays temperature set value Action please the temperature is not precisely controlled when you start an auto tuning p...

Page 9: ...ial function 0 1000S 350 T Control cycle The temperature control cycle 1 60S 5 Pb Zero point adjust When the zero error comparatively larger to update this value should be needed Pb actual value measu...

Page 10: ...the set temperature value is achieved 2 The timer start to work as soon as the instrument get to work 0 2 1 Hn Timer unit 0 Minute 1 Hour 0 1 0 SPD Timer parameter When measured value of temperature...

Page 11: ...occurs 2 when the timer starts to work 0 2 0 SPL Minimum set point The minimum temperature set point 50 0 50 0 SPH Maximum set point The maximum temperature set point 0 400 0 Parameter table 3 Paramet...

Page 12: ...for a long time should be set good plastic dust cover put in the dry room 6 Use of the abnormal phenomenon please cut off the power supply and promptly get in touch with our company VII Fault handlin...

Page 13: ...In the temperature sensor Temperature is out of control Temperature sensor is fixed Fixed temperature sensor Temperature controller is bad silicon controlled rectifier In the temperature sensor silico...

Reviews: