![HUAYUAN LG-125HA Manual Instruction Download Page 8](http://html1.mh-extra.com/html/huayuan/lg-125ha/lg-125ha_manual-instruction_2179864008.webp)
2
Voltage input
abnormal
Power on
Cutting
Power off
Gas checking
Grounding terminal
Current adjusting
Gas input
Cutting ground
cable
Gas/electricity output
Controlling signal
Guiding arc
Expanded metal
cutting
Plate metal cutting
2
Operation Environment
To get a good cutting performance, please operate this machine as below environmental requirement
1.
Please use the machine in a clear place without any of dust, corrosive gas and inflammables and explosives; Do not
use it in open air and rain;
2.
Required air relative humidity should ≤90
%
(at 20
℃
)
,
40
℃
≤50
%
(at 40
℃
)
;
3.
Environment temperature range should be at-10
℃~
40
℃
;
4.
Keep the machine away from the wall of some other closure things at least 30cm, two machines distance at least
30cm.
5.
Use it under altitude lower than 1000m.
3
Specifications and parameter
3.1
Main technical parameters
Name
Unit
Parameter
Rated input voltage
V/Hz
3
~
380/415V 50/60Hz
Rated input current
A
36.7
Rated input power
KW
18.0
Rated input capacity
KVA
24.1
No-load voltage
V
320
Power factor
-
0.74