Operating temperature: 5°C to 45°C (41°F to 113°F) (ASHRAE CLASS A2 to A4
compliant). For details, see
.
–
Storage temperature: -40°C to +65°C (-40°F to +149°F)
–
Temperature change rate: < 20°C/h (36°F/h)
Table 13-3
Operating temperature specifications
Model
Maximum
Operating
Temperatu
re 30°C
(86°F)
Maximum
Operating
Temperatu
re 35°C
(95°F)
(ASHRAE
CLASS A2
Compliant
)
Maximum
Operating
Temperature
40°C (104°F)
(ASHRAE
CLASS A3
Compliant)
Maximum
Operating
Temperature 45°C
(113°F) (ASHRAE
CLASS A4
Compliant)
Server with
eight 2.5-
inch drives
Supports all configurations.
l
Does not
support PCIe
SSD cards.
l
Does not
support
passive
cooling
GPUs.
l
Does not support
PCIe SSD cards.
l
Does not support
passive cooling
GPUs.
l
Supports only
Intel
®
Xeon
®
Platinum 8153
and Gold
6152/6140/6126/
5118 CPUs, and
CPUs lower than
105 W.
l
Does not support
rear drives.
l
Does not support
standard IB and
OPA cards.
Server with
twelve 3.5-
inch drives
(expander)
Supports all
configuratio
ns.
Does not
support
P100 and
M60 GPUs.
l
Does not
support PCIe
SSD cards.
l
Does not
support
passive
cooling
GPUs.
l
Does not
support rear
drives.
l
Does not
support built-
indrives.
N/A
Server with
twelve 3.5-
inch drives
(pass-
through)
2288H V5 Server