background image

8

Ensure that the locking 
nut is secured.

Ensure that the cables are 
correctly connected.
(The DC voltage of a multimeter
should not be less than 1100 V).

Click

Positive metal contact

Negative metal contact

Ensure that the cable 
cannot be pulled out 
after being crimped.

Negative 
connector

Positive connector

Pull back the DC input power cable to 
ensure that it is in position.

Click

DC input terminals 

Summary of Contents for SUN2000-(3KTL-12KTL)-M0

Page 1: ...SUN2000 3KTL 12KTL M0 Quick Guide HUAWEI TECHNOLOGIES CO LTD Issue 02 Part Number 31509649 Date 2018 12 30 ...

Page 2: ...kind express or implied 2 Before installing the device read the user manual carefully to get familiar with product information and safety precautions 3 Only qualified and trained electrical technicians are allowed to operate the device Operation personnel should understand the composition and working principles of the grid tied PV power system and local regulations 4 Before installing the device c...

Page 3: ...2 Dimensions Tilt and Space 2 Installing the Device Installation Requirements 2 1 ...

Page 4: ...onal Install an anti theft lock M6x60 expansion bolts are delivered with the SUN2000 If the length and amount of the bolts do not meet installation requirements prepare M6 stainless steel expansion bolts by yourself Loosen the nuts flat washers and spring washers of the two expansion bolts below NOTE 1 Install the mounting bracket When drilling holes avoid the water pipes and power cables buried i...

Page 5: ...tions Do not connect the neutral wire to the enclosure as a PE cable Otherwise electric shocks may occur No Item Type Specifications 1 PE cable Single core outdoor copper cable Conductor cross sectional area 4 mm2 2 AC output power cable Outdoor copper cable Conductor cross sectional area 4 6 mm2 Cable outer diameter 10 21 mm 3 DC input power cable Standard outdoor PV cable in the industry recomme...

Page 6: ... are totally inserted into the cable hole and the cable is connected securely Failing to do so may cause device malfunction or damage 1 Connect the AC output power cable to the AC connector Four core cable L1 L2 L3 and PE Three core cable L1 L2 and L3 Installing the AC Output Power Cable 3 3 Click Click ...

Page 7: ...6 Five core cable L1 L2 L3 N and PE AC output port AC Four core cable L1 L2 L3 and N 2 Connect the AC connector to the AC output port Click Click ...

Page 8: ...sure correct cable connections 5 Use the positive and negative metal contacts and black DC connectors supplied with the SUN2000 Using incompatible positive and negative metal terminals and DC connectors may result in serious consequences The caused device damage is not covered under any warranty 6 If the DC input power cable is reversely connected do not operate the DC switch as well as positive a...

Page 9: ...ltage of a multimeter should not be less than 1100 V Click Positive metal contact Negative metal contact Ensure that the cable cannot be pulled out after being crimped Negative connector Positive connector Pull back the DC input power cable to ensure that it is in position Click DC input terminals ...

Page 10: ...ously Steady on The Dongle is secured and powered on Red Blinking at short intervals on for 0 2s and off for 0 2s The parameters for connecting to the router are to be set Red Steady on Abnormal The Dongle is faulty Replace the Dongle Blinking red and green alternatively Blinking at long intervals on for 1s and off for 1s No communication with the inverter Remove and insert the Dongle Check whethe...

Page 11: ...tion Pin Definition Function Description 1 485A1 1 RS485A RS485 differential signal Used to connect to the RS485 signal port on the SUN2000 or SmartLogger 2 485A1 2 RS485A RS485 differential signal Used to connect to the RS485 signal port on the SUN2000 or SmartLogger 3 485B1 1 RS485B RS485 differential signal 4 485B1 2 RS485B RS485 differential signal 5 PE Shielding ground N A 6 PE Shielding grou...

Page 12: ...A2 and 485B2 Only one device can be connected to the GPRS Smart Dongle Two types of 4G Smart Dongles are available connecting a maximum of two and ten devices respectively A maximum of ten devices can be connected to the WLAN Smart Dongle If a grid scheduling device needs to be connected to the link it must be connected to the same inverter as the Smart Dongle Smart Dongle Networking SmartLogger N...

Page 13: ...r more SUN2000s are cascaded install RS485 communications cables Optional Installing the RS485 Communications Cable 1 Connect the signal cable to the signal cable connector 2 Connect the signal cable connector to the Communication port ...

Page 14: ...13 Optional Installing the Smart Power Sensor Signal Cable 1 Connect the signal cable to the signal cable connector 2 Connect the signal cable connector to the Communication port Communication port COM ...

Page 15: ... Connect the signal cable to the signal cable connector 2 Connect the signal cable connector to the Communication port Optional Installing the Grid Scheduling Dry Contact Signal Cable Communication port COM ...

Page 16: ...tributed and no burr exists 5 The PE cable is connected correctly securely and reliably 6 The DC switch and all the switches connected to the SUN2000 are set to the OFF position 7 The AC output power cable DC input power cable and signal cable are connected correctly securely and reliably 8 Unused terminals and ports are locked by watertight caps 9 The installation space is proper and the installa...

Page 17: ... non China versions Off Off China version DC is off and AC may be energized Ensure that the external AC switch is OFF Non China versions DC is off and AC is on Blinking red at short intervals N A DC environmental alarm N A Blinking red at short intervals AC environmental alarm Steady red Steady red Faulty Communication indicator N A Blinking green at short intervals Communication is in progress Wh...

Page 18: ...nted by SUN2000 Serial number SN The SN is available on the label attached to the side of the SUN2000 Use the initial password Changeme upon first login To ensure account security change the password immediately after login If you log in for the first time and the initial SUN2000 WiFi password is not changed you can scan the WiFi login QR code on the side of the SUN2000 to connect to the SUN2000 W...

Page 19: ...18 iOS WLAN WLAN WLAN WLAN The initial password is Changeme The initial password is 00000a WLAN ...

Page 20: ...unt Registration WLAN WLAN If there is an available WLAN network use it If there is not disable WLAN and use Mobile Data WLAN WLAN NOTE Skip this step if you already have an installer account Connecting the Phone to the Internet iOS is used as an example ...

Page 21: ...k network settings Creating a New PV Plant Internet connection required Check network settings NOTE Scan the QR code on the right to obtain the operation guide for quick settings and creating a new PV plant Creating a New Account for User ...

Page 22: ...an Japan_ESC ms huawei com 0120258367 India India indiaenterprise_TAC huawei com 1800 103 8009 South Korea South Korea Japan_ESC ms huawei com North America USA na_inverter_support huawei com 1 877 948 2934 Canada na_inverter_support huawei com 1 855 482 9343 Latin America Mexico la_inverter_support huawei com 018007703456 0052 442 4288288 Argentina 0 8009993456 Brazil 0 8005953456 Chile 800201866...

Page 23: ...Huawei Technologies Co Ltd Huawei Industrial Base Bantian Longgang Shenzhen 518129 People s Republic of China solar huawei com ...