Alarm
ID
Alarm Name
Alarm
Severity
Possible Causes
Troubleshooting
2068
Battery
Abnormal
Minor
The battery is faulty,
disconnected, or the
battery circuit breaker is
OFF when the battery is
running.
Cause ID = 1–4
ɲ ǁǿf¯ììàă
communication is
abnormal.
ɲ ǂǿf¯ììàăÝÑàì
experiences overcurrent.
ɲ ǃȇf¯ììàăÊòʪ
cable is not properly
connected.
ɲ DŽǿf¯ììàăÝÑàì
voltage is abnormal.
1. If the battery fault
indicator is steady on or
blinking, contact the
battery supplier.
2. Check that the battery
enabling/power/
communications cable is
correctly installed, and
that the
communications
parameters are the
same as the SUN2000
RS485 ÑÊĒªñàì²ÑÊäȇ
3. Check that the auxiliary
power switch on the
battery is set to ON.
4. Send a shutdown
command on the app.
Turn Ñč the AC output
switch, DC input switch,
and battery switch. Then
turn on the battery
switch, AC output
switch, and DC input
switch in sequence after
5 minutes.
5. If the fault persists,
contact your dealer or
Huawei technical
support.
2070
Active Islanding Major
Cause ID = 1
When the power grid
experiences an AC power
outage, the SUN2000
detects islanding
proactively.
Check that the grid
connection voltage of the
SUN2000 is normal.
SUN2000-(2KTL-6KTL)-L1
User Manual
8 System Maintenance
Issue 03 (2020-09-15)
Copyright © Huawei Technologies Co., Ltd.
90