![Huawei SUN2000-(2KTL-6KTL)-L1 User Manual Download Page 40](http://html.mh-extra.com/html/huawei/sun2000-2ktl-6ktl-l1/sun2000-2ktl-6ktl-l1_user-manual_168464040.webp)
No. Cable
Type
Recommended
^ݲĒì²ÑÊä
Source
3
(Optional)
Signal
cable
Outdoor shielded
twisted pair cable
ɲ ÑÊñìÑààÑääȝ
sectional area:
– Combined
crimping of
cables on the
port: 0.20–0.35
mm
2
– Crimping the
cables on the
port without
combining
them: 0.20–1
mm
2
ɲ ÃÑñìà
diameter:
– 4-hole rubber
plug: 4–8 mm
– 2-hole rubber
plug: 8–11 mm
Prepared
by the
customer
4
AC output
power
cable
a
ɲ EÑìñä²Êªì¯W
equipotential point
at the AC output
port: two-core (L
and N) outdoor
copper cable
ɲ kä²Êªì¯W
equipotential point
at the AC output
port: three-core (L,
N, and PE) outdoor
copper cable
ɲ ÑÊñìÑààÑääȝ
sectional area: 4–6
mm
2
ɲ ÃÑñìà
diameter: 10–21
mm
Prepared
by the
customer
5
PE cable
Single-core outdoor
copper cable and M6
OT terminal
4–10 mm
2
Prepared
by the
customer
Note a: The minimum cross-sectional area of the cable should be selected based
on the rated value of the AC fuse.
NO TE
ɲ f¯É²Ê²ÉñÉòÉìàÉñäìÑÉÝÃăý²ì¯ÃÑÃÃäìÊàäȇ
ɲ f¯©ìÑàäì¯ìčì cable selection include the rated current, cable type, routing
mode, ambient temperature, and maximum expected line loss.
SUN2000-(2KTL-6KTL)-L1
User Manual
5 Electrical Connection
Issue 03 (2020-09-15)
Copyright © Huawei Technologies Co., Ltd.
34