background image

 

Configuring the MT883 

4.1 

Changing the Administrator Password Used 

for Logging In to the Web Configuration Page 

For safety reasons or to make the password easy to remember, you can change the 
log-in administrator password after logging in to the Web configuration page. 

To change the password, do as follows: 

Step 1

 

Choose 

Tools

 > 

System Management

 in the navigation tree to display the 

system management page. 

Step 2

 

Click 

 to display a dialog box. 

Step 3

 

Enter the old password and the new password, and then enter the new 
password again in the 

Retype to confirm

 text box for confirmation. 

Step 4

 

Click 

Submit

After you change the password successfully, the current page jumps to the page for 
logging in to the Web configuration page. To log in to the Web configuration page, 
enter the new password, and then click 

OK

 

If you cannot remember the user name and password that have been 
changed, you can restore the default settings of the MT883 by pressing 
the RESET button on the panel. In this way, the user name and the 
password used for logging in to the Web configuration page are restored 
to default values. 

4.2 

Changing the IP Address 

To make the IP address easy to remember, you can change the IP address after logging 
in to the Web configuration page. 

To change the IP address, do as follows: 

Step 1

 

Choose 

Basic

 > 

LAN Setting

 in the navigation tree to display the LAN 

settings page. 

Step 2

 

Enter a new IP address in the 

IP Address

 text box. 

Step 3

 

Click 

Submit

After the IP address is changed successfully, to log in to the Web configuration page, 
you need to launch the Internet Explorer and enter the new IP address in the address 

bar

.

Ensure that the IP address of the computer is in the same network segment as that 

Summary of Contents for SmartAX MT883

Page 1: ...SmartAX MT883 ADSL CPE User Guide HUAWEI TECHNOLOGIES CO LTD ...

Page 2: ...SmartAX MT883 ADSL CPE V100R001 User Guide Issue 01 Date 2008 11 20 Part Number 103127 ...

Page 3: ...be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co Ltd Trademarks and Permissions and other Huawei trademarks are trademarks of Huawei Technologies Co Ltd All other trademarks and trade names mentioned in this document are the property of their respective holders Notice The information in this document is subject to change without notic...

Page 4: ...ameters 7 3 1 Accessing the Network Through the Embedded PPP Dial Up Software of the MT883 7 3 2 Accessing the Network Through the PPP Dial Up Software on the Computer 8 4 Configuring the MT883 9 4 1 Changing the Administrator Password Used for Logging In to the Web Configuration Page 9 4 2 Changing the IP Address 9 4 3 Restoring Default Settings 10 5 FAQs 10 6 Appendix 13 6 1 Indicators 13 6 2 In...

Page 5: ...6 3 Default Settings 14 6 4 Technical Specifications 14 ii ...

Page 6: ...rformance design of the device z While using the device observe all applicable laws directives and regulations and respect the legal rights of other people Environmental Requirements z Place the device in a well ventilated place Do not expose the device to direct sunlight z Keep the device clean free of dust and stain z Do not place the device near a water source or in a damp area z Place the devi...

Page 7: ...the power supply and unplug all the cables connected to the device such as the power cable telephone cable and RF cable to prevent lightning strike z If the device is not used for a long time disconnect the power supply and unplug the all the cables connected to the device z If smoke sound or smell is emitted from the device stop using the device immediately disconnect the power supply unplug the ...

Page 8: ...pose it according to the local regulations on disposing of device packing materials exhausted battery and abandoned device and support the recycling activity After the MT883 is used for a certain period of time the cover will be heated which will not affect the function of the MT883 ...

Page 9: ...ple Connection If your telephone line is used for the broadband network access only and you do not need to use a telephone take the following figure as a reference for connecting the cables POWER LAN RESET 2 1 ADSL 1 Telephone jack on the wall 2 Computer ...

Page 10: ...ephone line is used for both the broadband network access and a telephone connection take the following figure as a reference for connecting the cables POWER LAN RESET 1 2 3 4 ADSL 1 Telephone jack on the wall 2 Splitter 3 Telephone 4 Computer ...

Page 11: ...T connector 3 Microfilter 4 Splitter 5 Telephone 6 Fax 7 Computer 2 4 Getting Started Step 1 Power on the computer Step 2 Press the power button on the top of the MT883 After you power on the MT883 the ADSL indicator blinks indicating that the MT883 is being activated Later the ADSL indicator becomes on The POWER indicator is also on indicating that the MT883 is working To power off the MT883 pres...

Page 12: ...ttp 192 168 1 1 in the address bar and press Enter 2 In the displayed dialog box enter the user name and the password and then click OK By default both the user name and the password are admin After the password is verified you can access the Web configuration page Step 2 Enable the embedded dial up function 1 In the navigation tree on the left of the configuration page choose Basic WAN Setting 2 ...

Page 13: ...erating system as an example 1 Choose Start All Programs Accessories Communications Network Connections 2 Click Create a new connection in Network Tasks to display the New Connection Wizard window and then click Next 3 Select Connect to the Internet and then click Next 4 Select Set up my connection manually and then click Next 5 Select Connect using a broadband connection that requires a user name...

Page 14: ...onfiguration page enter the new password and then click OK If you cannot remember the user name and password that have been changed you can restore the default settings of the MT883 by pressing the RESET button on the panel In this way the user name and the password used for logging in to the Web configuration page are restored to default values 4 2 Changing the IP Address To make the IP address e...

Page 15: ... terminal is properly connected to the socket through the USB cable If the POWER indicator is still off contact an authorized maintenance center Step 2 After powering on the terminal wait for about three minutes Then check whether the ADSL indicator of the terminal is on If the ADSL indicator blinks for a long time perform further checks as follows 1 Ensure that telephone lines are properly connec...

Page 16: ... of the computer If no network adapter is found or if a question mark or an exclamation mark is displayed next to the icon of the network adapter you can infer that the driver for th network adapter is not properly ins network adapter of the computer Ensure that you have entered the correct u are required by the PPP dialing software The use name and the user password are provided by your network o...

Page 17: ...fected Check the positions of your terminal and computer Ensure that they are far from the electric appliances such as microwave ovens refrigerators cordless telephones that generate strong mag If After a broadband terminal is installed does Internet access degrade call quality or do telephone calls lower the Internet access rate No The terminal uses the frequency division multiplexing FDM and spl...

Page 18: ... and Buttons Interface Butto n Description POWER It is used to connect to the USB port on the computer The power is supplied to the MT883 through the USB port on the computer LAN It is used to connect to the Ethernet interface on the computer RESET You can restore the default settings by pressing this button Note After you restore the default settings the customized data will be lost Therefore use...

Page 19: ...1 G hs ANSI T1 413 Issue 2 ADSL2 standard ITU G 992 3 G dmt bis Annex A Standards ADSL2 standard ITU G 992 5 Annex A G dmt T1 413 z Maximum downstream rate 8 Mbit s z Maximum upstream rate 896 kbit s Data transmission G 992 5 ADSL2 z Maximum downstream rate 24 Mbit s z Maximum upstream rate 1024 kbit s Power supply for the MT883 The power supply is provided through the USB port on the computer Pow...

Page 20: ...HUAWEI TECHNOLOGIES CO LTD Huawei Industrial Base Bantian Longgang Shenzhen 518129 People s Republic of China www huawei com Part Number 103127 ...

Reviews: