Step 9
Run the
load packetfile
command to load the board software. After the board software is loaded,
wait about five minutes, and then check whether the new board works properly.
l
If the new board works properly, go to
.
l
If the new board does not work properly, go to
Step 10
Record the results of the preceding steps in a fault report (see Fault Report Form), fill out the
entire form, and then submit it to Huawei for technical support (see
Step 11
End.
----End
6.7 Unexpected Reset of the System
This section describes how to troubleshoot unexpected reset of the system. When the system is
reset unexpectedly, all services carried on the device are interrupted and the device cannot be
managed by the network management system (NMS).
Location Method
Use the following guidelines to locate the fault:
1.
Check whether the user has issued a command to reset the device.
2.
Check whether the power supply for the device is normal.
3.
Check whether the device temperature is within the acceptable range.
CAUTION
To facilitate fault report, save the results of the following steps.
Procedure
Step 1
Run the
display log all
command to check whether the user has issued a command to reset the
device.
l
If the device is reset following the execution of a reset command, go to
l
If no command has been issued to reset the device, go to
.
SmartAX MA5612 Multi-service Access Module
Maintenance Guide
6 System Fault Handling
Issue 01 (2012-07-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
237