Follow-up Procedure
If the remote extended frame cannot be discovered, follow the troubleshooting suggestions listed
in the following table to rectify faults.
Possible Cause
Troubleshooting Suggestion
The D-CMTS works as a
standalone NE and cannot
work as a remote extended
frame.
Replace the D-CMTS with the one that works as a remote
extended frame.
The D-CMTS management
policy is set to
stand-alone
on
the OLT.
Run the
sysman centralized-mgmt primary
command to
configure the D-CMTS management policy to
extend-
frame
.
The number of remote
extended frames on the OLT
has reached the threshold.
Run the
frame delete
command to delete a remote extended
frame that is no longer used from the OLT.
The working mode of the ports
on the remote extended frame
is not
extend
.
In Ethernet mode, run the
network-role extend
command
to set the working mode of the ports to
extend
.
15.4.1.8 Configuring RF Port Parameters
Radio frequency (RF) port parameters define the frequency spectrum range for signal
transmission and modulation mode. The configuration of RF port parameters implements data
service transmission over cables.
Context
You can use either of the methods listed in the following table to configure RF port parameters
based on site requirements.