RRU3832&RRU3632
Installation Guide
8 Installing the RU
Issue 05 (2014-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
52
8.2 Installing the RU on a Pole
One or more RUs can be installed on a pole.
8.2.1 Installing a Single RU
This section describes the procedure and precautions for installing a single RU on a pole.
Prerequisites
Before you install an RU on a pole secured on a tower, the RU and its mounting brackets are
hoisted onto the tower. For details, see
7.1 Hoisting an RU onto a Tower
The hoist clamp on the main bracket is secured properly.
Do not stand the RU upright because the RF ports cannot support the weight of the RU.
Place a foam pad or cardboard under the RU to protect the RU housing from damage
during the installation.
Procedure
Step 1
Determine a position for installing the mounting brackets.
If the pole must be installed on a tower, determine a position for installing the mounting
brackets according to the instructions in
3.5.1 Clearance for a Single RU
If the pole must be installed on the ground, determine a position for installing the
mounting brackets according to
Figure 8-3
Distance between the mounting brackets and the ground