References for Installation
Loading Configuration Data and Measuring the RSL
WLAN module
Web LCT
Open the maintenance compartment.
Load configuration data.
Close the maintenance compartment.
RSL tester
Measure the RSL.
If the RSL is lower than the required value, re-align the
RTN 360 pair.
Verifying the Installation
1
2
3
4
5
6
7
8
9
22/23 >>
Verify that RTN 360s are installed in planned locations and sufficient space is reserved
for maintenance.
Verify that the RTN 360s are securely installed. Attempt to gently turn the boxes
vertically and horizontally. If the RTN 360s do not move, they are securely installed.
Verify that OT terminals of PGND cables are tightly crimped and PGND cables are not
damaged or broken.
Verify that PGND cables are bound separately from other cables.
Verify that the protection ground of an RTN 360 shares the same ground bar with the
lightning protection ground of the building bearing the RTN 360.
Verify that shielded RJ45 connectors of outdoor network cables are intact and tightly
crimped and the cables are not damaged or broken.
Verify that PG covers are tightly screwed onto the network ports of RTN 360s, unused
ports are protected with caps, and removed caps are retained for future use.
Verify that outdoor network cables are routed along planned paths and bound properly
and neatly at equal intervals (about 1 meter), and the excess of each cable tie is cut off
without leaving sharp edges.
Verify that alignment scopes are removed and securely stored.
If a WLAN module is installed at the USB port, you can determine whether the WLAN module is working properly
by enabling it to search for the SSID of an NE in the wireless LAN. If the SSID can be searched out, the WLAN
module is working properly. If the SSID cannot be searched out, open the maintenance compartment and view
the WLAN module indicator. If the indicator is steady red, replace the WLAN module.