Huawei R50040G1 Quick Manual Download Page 1

1

Indicator

Status

Description

Running 
indicator 
(green)

Steady on (normal 
status)

The charger has an AC input.

Off

The charger has no AC input.

Blinking at 0.5 Hz

The charger is being queried.

Blinking at 4 Hz

An application is being loaded.

Alarm 
indicator 
(yellow)

Off (normal status)

The charger has no protection alarms.

Steady on

Ambient overtemperature alarm

AC input overvoltage, undervoltage, open phase, or 
serious voltage imbalance

Slight current imbalance

Soft address abnormality alarm

Ambient undertemperature alarm 

Protection caused by other abnormalities

Blinking

The charger has failed to communicate. 

Fault 
indicator 
(red)

Off (normal status)

The charger is fault-free.

Steady on

Lockout due to output overvoltage

Serious current imbalance

Fan fault

Communication failure between the primary side 
and the secondary  side

Unrecoverable no-output breakdown

Poor connection

Lockout due to an output short circuit

Abnormal detection of the hardware address board

Abnormal output discharge circuit

Faults caused by other abnormalities

Power 
indicator

Steady on

Indicates the output power.

600 W < output power ≤ 4000 W: One indicator is 
on.

4000 W < output power ≤ 8000 W: Two indicators 
are on.

8000 W < output power ≤ 12000 W: Three 
indicators are on.

12000 W< output power ≤ 16000 W: Four indicators 
are on.

Output power > 16000 W: Five indicators are on.

Issue: 02
Part Number: 31509297
Date: 2018-06-15

R50040G1 Charger 
Quick Guide

1

Overview

2

Installing the Charger

(1) Power indicators

(2) Running indicator

(3) Alarm indicator

(4) Fault indicator

(5) Warranty label

(6) Barcode

(7) Mounting ear 
(optional) 

(8) DC output port

(9) AC input port

Model

R50040G1

Weight

12 kg (without packaging)

14 kg (with packaging)

Dimensions (H x W x D)

83 mm x 206 mm x 470 mm

The charging machine (pile) or station should comply with the environment protection requirements in sections 6.3 and 8.3 of NB/T33001-2010 as well as the 
environment resistance and protection level requirements in NB/T33008.1-2013. They should provide the protection rating of at least IP54 outdoors or IP30 
indoors when used in common environments.

Avoid using the product in sea environments or outdoor land environments (with simple shielding measures) near pollution sources. If such an environment is 
unavoidable, the charging machine (pile) should provide the protection rating of IP65. Otherwise, the product may become faulty, and the resulting product 
malfunction or component damage is beyond the warranty  scope. Pollution sources refer to the following areas:

Areas within 3.7 km away from salt water such as the sea

Areas within 3 km away from serious pollution sources, such as metallurgic plants, coal mines, and heat and power plants

Areas within 2 km away from medium pollution sources, such as chemical factories, rubber plants, and electroplating factories

Areas within 1 km away from light pollution sources, such as food factories, tanneries, and heating boilers

Installation Environment and Hole Size Requirements

2.1

Installing the Charger

2.2

Application scope: charging machine (pile) or station

The charger can be installed horizontally, sidewards, or vertically (with the panel at the bottom). If side or vertical installation is adopted, ensure that mechanical 
parts are designed to avoid interference.  The installation mode can be selected according to the actual situation. Horizontal installation is recommended and vertical 
installation is not recommended.

Front

Rear

Avoid using the product in an environment with corrosive or insulation-damaging materials. 
If such an environment is unavoidable, the charging machine (pile) should provide the 
protection rating of IP65. Otherwise, the product may become faulty, and the resulting 
product malfunction or component damage is beyond the warranty scope.

• It is recommended that the ventilation area for a single charger be 11500 mm

2

, and the 

minimum ventilation area be 9000 mm

2

. The ventilation area of the system is calculated 

based on the number of chargers. (The data is only the area required for heat dissipation of 
the charger but not other devices.)

• It is recommended that the air inlet and outlet of the charger be at least 40 mm away from 

the cabinet. The specific distance depends on the air channel of the system.

Mounting Hole Sizes (unit: mm)

Copyright © Huawei Technologies Co., Ltd. 2018. All rights reserved.

1. The information in this document is subject to change due to version upgrades or other reasons. Every effort has been made in the preparation of this document to 

ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty  of any kind, express or implied.

2. Before installing the device, carefully read the user manual to get familiar with product information and safety precautions. You can log in to 

http://support.huawei.com/carrier/ and search for the device model on the Product Support tab page to view or obtain the user manual.

3. Only qualified and trained electrical technicians are allowed to operate the device. Operation personnel must wear proper personal protective equipment (PPE) all 

the time.

4. Before installing the device, check that the product and accessories are intact and complete. If any damage is found or any component is missing, contact your 

supplier.

5. When operating Huawei equipment, follow the precautions and special safety instructions provided by Huawei. Huawei will not be liable for any consequences that 

are caused by the violation of safety regulations and design, production, and usage standards.

6. Do not remove the warranty  label or barcode from the charger. Otherwise, product warranty will be forfeited.

NOTICE

Summary of Contents for R50040G1

Page 1: ...llution sources such as chemical factories rubber plants and electroplating factories Areas within 1 km away from light pollution sources such as food factories tanneries and heating boilers Installation Environment and Hole Size Requirements 2 1 Installing the Charger 2 2 Application scope charging machine pile or station The charger can be installed horizontally sidewards or vertically with the ...

Page 2: ...ss sectional area 0 08 mm2 maximum cross sectional area 1 5 mm2 wire minimum cross sectional area 28 AWG wire maximum cross sectional area 16 AWG Preparing Cables 3 1 Side Installation Vertical Installation Not Recommended Horizontal Installation Recommended 1 Optional Determine whether to install the mounting ear based on the site requirement 2 Slowly push the charger into the slot 3 Tighten the ...

Page 3: ... The address extension function is disabled Two address setting switches are used on the address board to set the address Up to 36 addresses can be set Hardware address Row address 1 x 6 Column address The address extension function is enabled One extension switch and two address setting switches are used on the address board to set the address Up to 64 addresses can be set Hardware address Extend...

Page 4: ...that the CAN communications cable is correctly connected and the build out resistor is installed as required If the alarm persists contact Huawei customer service center Fault indicator red Steady on Lockout due to output overvoltage Serious current imbalance Fan fault Communication failure between the primary side and the secondary side Unrecoverable no output breakdown Poor connection Lockout du...

Reviews: