![Huawei Quidway S5600 Installation Manual Download Page 68](http://html.mh-extra.com/html/huawei/quidway-s5600/quidway-s5600_installation-manual_169840068.webp)
Installation Manual
Quidway S5600 Series Ethernet Switches
Chapter 6 Maintenance and Troubleshooting
Huawei Technologies Proprietary
6-2
I. No information on the terminal
Take these steps to address the problem:
1) Check
that:
z
The power system is operating normally.
z
The console cable is connected correctly.
2) Check that the console cable is in good condition and the terminal (HyperTerminal
for example) parameter settings are correct.
II. Illegible characters on the terminal
Make sure you have set on your terminal (HyperTerminal):
Baud rate = 9600
Databit = 8
Parity check = none
Stopbit = 1
Flow control = none
Terminal emulation = VT100
Reconfigure the parameters if their values are different.