supp-timeout-value
: Specify how long the duration of an authentication timeout timer of
a Supplicant is. The value ranges from 10 to 120 in units of second and defaults to 30.
tx-period
: Specify the transmission timeout timer. After the Authenticator sends the
Request/Identity request packet which requests the user name or user name and
password together, the tx-period timer of the Authenticator begins to run. If the
Supplicant does not respond back with authentication reply packet successfully, then
the Authenticator will resend the authentication request packet.
tx-period-value
: Specify how long the duration of the transmission timeout timer is. The
value ranges from 10 to 120 in units of second and defaults to 30.
reauth-period
: Re-authentication timeout timer. During the time limit set by this timer,
the supplicant device launches 802.1x re-authentication.
reauth-period-value
: Period set by the re-authentication timeout timer, ranging from 1 to
86400, in seconds. By default, the value is 3600.
ver-period
: Client version request timeout timer. If the supplicant device failed to send
the version response packet within the time set by this timer, then the authenticator
device will resend the version request packet.
ver-period-value
: Period set by the version request timeout timer, ranging from 1 to 30,
in seconds. By default, the value is 1.
1.2.13 Enabling/Disabling a Quiet-Period Timer
You can use the following commands to enable/disable a quiet-period timer of an
Authenticator (which can be a Quidway Series Ethernet Switch). If an 802.1x user has
not passed the authentication, the Authenticator will keep quiet for a while (which is
specified by
dot1x timer quiet-period
command) before launching the authentication
again. During the quiet period, the Authenticator does not do anything related to 802.1x
authentication.
Perform the following configuration in system view.
Table 1-16
Enabling/disabling a quiet-period timer
Operation
Command
Enable a quiet-period timer
dot1x quiet-period
Disable a quiet-period timer
undo dot1x quiet-period
By default,
quiet-period
timer is disabled.
1.3 Displaying and Debugging 802.1x
After the above configuration, execute
display
command in any view to display the
running of the VLAN configuration, and to verify the effect of the configuration. Execute