Technical Specifications
OptiX OSN 3500 TM - SD
7-16
4. Mechanical stress
Table 7-21
Requirements for mechanical stress
Item
Sub-item
Range
Shift
= 7.5mm
-
-
Acceleration
-
= 20.0m/s²
= 40.0m/s²
Sinusoidal
vibration
Frequency range
2 ~ 9Hz
9 ~ 200Hz
200 ~ 500Hz
Acceleration
spectral density
10m²/s³
3m²/s³
1m²/s³
Random
vibration
Frequency range
2 ~ 9Hz
9 ~ 200Hz
200 ~ 500Hz
Impact response
spectrum II
= 300m/s²
Non-steady
impact
Static load
= 10kPa
Note:
Impact response spectrum: the curve of the maximum acceleration response
generated by the equipment under the stipulated impact motivation. Impact response
spectrum II indicates the duration of semi sinusoidal impact spectrum is 6ms.
Static load: The pressure from upside, that the equipment with package can endure
when the equipment is piled as per stipulation.
7.9.3 Environment for Operation
1. Climate
Table 7-22
Requirements for temperature and humidity
Temperature
Relative humidity
Equipment
name
Long-term
operation
Short-term
operation
Long-term
operation
Short-term
operation
OptiX OSN 3500
0
°
C ~ 40
°
C
-5
°
C ~ 55
°
C
10% ~ 90%
5% ~ 95%
Note:
The temperature and humidity values are obtained 1.5m above the floor and 0.4m in
front of the equipment.
Short-term operation means the consecutive working time of the equipment does not
exceed 96 hours, and the accumulated working time every year does not exceed 15
days.