14
Installing the Input Power Cable for the OMB Cabinet (AC Power Supply)
a
a
b
b
a
N
PE
L
Installing the Input Power Cable for the RTN 905
b
2
NOTE
2
1
1
When installing power cables for the RTN 905, ensure that the power
cables are correctly connected to the positive and negative terminals of
the power distribution box.
2
Installing and Routing the Power Cables
– AC Power Supply
For AC OMB cabinets of Ver. C, connect the two power cables from
RTN 905 to any two power output terminals (such as terminals LOAD6
and LOAD7) with the maximum output current of 30 A. For information
about assembling the easy power receptacle (pressfit type) connector,
see "Appendixes ".